No Detail Found!

Electrical Resistivity Sur vey by Schlumberger Electrode Configuration Technique for Ground Water Exploration in Pakistan

Author(s)
Talat Farid Ahmed Farm Operations and Services, National Agricultural Research Centre,Park Road Islamabad,Pakistan
Muhammad Azeem Afzal Farm Operations and Services, National Agricultural Research Centre,Park Road Islamabad,Pakistan
Hashim Nisar Hashmi Civil Engineering Department, University of Engineering and Technology,Taxila,Pakistan
Hafiz Muhammad Yousuf Civil Engineering Department, University of Engineering and Technology,Taxila,Pakistan
Shamim-ul-Sibtain Shah Farm Operations and Services, National Agricultural Research Centre,Park Road Islamabad,Pakistan
Muhammad Atiqullah Khan Farm Operations and Services, National Agricultural Research Centre,Park Road Islamabad,Pakistan
Abstract
Aquifer zones had been explored by the geo-electrical method of electrical resistivity survey (ERS) to mark out subsurface formations in terms of groundwater quality and quantity. The main focus was on identification of subsurface litho-logy and aquifer zones by resistivity method in parts of the Havelian Cantt, Abbottabad district, Khyber Pakhtunkhwa (KPK) Province and Sanjwal Cantt, Attock district, Punjab Province, Pakistan. Evaluation of the lithology of subsurface strata was carried out by electrical resistivity survey (ERS) interpreted by software packages 1X1D using ABEM Terrameter SAS-4000. The diferent 05 sites were selected for ERS after identifying feasible locations. Data acquired was processed using the Schlumberger electrode configuration (SEC) to determine the characteristics of target layer. The results showed that groundwater level (GWL) at Havelian Cantt sites was at 69 ft average depth with resistivity values between 35-56 ohm-m and formation consist of dominance of gravel/boulder mixed with sand/ sand stone and thin layers of clay. GWL at Sanjwal Cantt sites was at 50 ft average depth having low to moderate yield of water and the formation had dominance of sand with alternate layers of clay against resistivity between 25-86 ohm-m. The study concluded that electrical resistivity survey (ERS) is a sound method for measuring GWL in sandy aquifers and boulder clayey formations when GWL is suficiently deep.
Publication Details
Page(s) 558-568
Published Journal: Pakistan Journal of Agricultural Research, Volume: 35, Issue: 3, Year: 2022

Request the full text from PASTIC

Keywords
Subsurface litho-logy of strata, Groundwater exploration, Resistivity survey, Schlumberger electrode configuration
0

Citations

0

Downloads

44

Views