No Detail Found!

Self-constituted modified del Nido cardioplegia solution in pediatric congenital heart defect surgery.

Author(s)
Iqbal Hussain Pathan PAQSJ Institute of Medical Sciences, GAMBAT, Pakistan
Jai Parkash Lady of Lourdes Hospital, Ireland
Naresh Kumar Lady of Lourdes Hospital, Ireland
Muhammad Farhan Khan PAQSJ Institute of Medical Sciences, GAMBAT.Pakistan
Naveed Nek Markhand PAQSJ Institute of Medical Sciences, GAMBAT.Pakistan
Abid Ali Soomro PAQSJ Institute of Medical Sciences, GAMBAT.Pakistan
Abstract
Objective: To present our experience of modified del Nido Cardioplegia for chemical arrest and myocardial protection during congenital heart defect repair pediatric cardiac surgeries. Study Design: Retrospective Cross Sectional. Setting: Department of Cardiac Surgery, PAQSJIMS, Gambat, Khairpur. Period: 15th March, 2021 to 10th October, 2022. Material & Methods: del Nido solution is generally constituted in plasma lyte A solution, not available in Pakistan; therefore, we constituted del Nido solution in ringer lactate solution. We had collected our data retrospectively for our study to assess the safety and efficacy of modified del Nido cardioplegic arrest during the open heart surgeries for congenital heart defects. We report clinical outcomes of our patients that include spontaneous rhythm, ionotropic score and duration of mechanical ventilation in patients underwent open heart surgeries. Results: During the study period we had performed 102 surgeries for correction or palliation of congenital heart defects. We have included 54 patients in our study with 28 (52%) male and 26 female (48%) patients; had a mean age 8.9 (±3.7) years and mean weight 22.4 (±12.7) kg. Majority of patients 29 (54%) belonged to Category 2 on RACHS-1 scale. Our average cross clamp time was 39.7min, and 37(68%) patients required a single dose of cardioplegia. Spontaneous sinus rhythm was established in 48(89%) patients; average ionotropic score of patients at the time of PICU arrival was 8.6 (±5.6) with 31(57%) have score of less than 10, while 2(4%) patients were received without the ionotrope. All the patients were shifted on mechanical ventilators with average time of 253.6 (±219.6) min of mechanical ventilation. Conclusion: Our results show modified del Nido solution is safe, with added benefits of fewer interruption in surgery, greater magnitude of spontaneous sinus rhythm and fewer ionotropic requirements
Publication Details
Page(s) 1247-1252
Published Journal: Professional Medical Journal, Volume: 30, Issue: 10, Year: 2023

Request the full text from PASTIC

Keywords
Cardiac surgery, Congenital heart defects, Pediatric cardiac surgery, Cardiopilegia, del Nido Solution, Ringer Lactate.
0

Citations

0

Downloads

52

Views