No Detail Found!

Clinical Study of Artificial Intelligence in Imaging Diagnosis of False Positive Lesions of Pulmonary Nodules

Author(s)
He Sun School of Clinical Medicine, Weifang Medical University, Weifang, Shandong, China; Department of Thoracic Surgery, Jinan Central Hospital, Jinan, Shandong, China
Jiaheng Wei School of Clinical Medicine, Weifang Medical University,Weifang, Shandong,China
Junfu Wang Department of Thoracic Surgery, Jinan Central Hospital,Jinan, Shandong,China
Zhanyue Pang Department of Thoracic Surgery, Jinan Central Hospital,Jinan, Shandong,China; Department of Thoracic Surgery, Jinan Central Hospital, Shandong University,Jinan, Shandong,China
Liangming Zhu Department of Thoracic Surgery, Jinan Central Hospital, Shandong University,Jinan, Shandong,China; Department of Thoracic Surgery, School of Medicine, Cheeloo College of Medicine, Shandong University,Jinan, Shandong,China
Abstract
Objective: To determine the accuracy of diagnosis of pulmonary nodules using arti cial intelligence method. Study Design: Observational study. Place and Duration of the Study: Department of Thoracic Surgery, Jinan Central Hospital, Jinan, China, from January 2020 to May 2021. Methodology: An analysis of clinical characteristics exhibited by 32 patients initially diagnosed with malignant tumours through imaging (LDCT) and arti cial intelligence (AI), was reclassi ed as having benign lesions following surgical intervention. Quantitative parameters were assessed, including CT mean value, kurtosis, skewness, solid ratio, and the ratio of length to short diameter, within a cohort of 32 benign patients juxtaposed with 58 patients diagnosed with lung cancer during the same time frame. The AI-derived parameters were subjected to Mann-Whitney U non-parametric test. Results: A total of 32 benign pulmonary lesions were evaluated that were initially misdiagnosed as malignant prior to surgery. These lesions displayed an average length of (18.56 ± 12.16) mm, with the majority characterised as solid (68.8%). Notably, a substantial proportion of these lesions exhibited imaging features akin to malignant growths. The AI-derived quantitative parameters of the 32 benign cases and the 58 malignant cases revealed statistical signi cance in average CT value and solid ratio. However, statistical signi cance was not established for kurtosis, skewness, or the ratio of length to short diameter. The area under the Receiver Operating Characteristic (ROC) curve for average CT value and solid ratio stood at 0.71 and 0.705, respectively. Conclusion: Among the cases initially misdiagnosed as malignant yet subsequently identi ed as benign, a notable number of these instances were solid nodules, often resembling malignant lesions in imaging characteristics. There was moderate discriminatory capacity for average CT value and solid ratio, rendering them valuable tools for distinguishing between benign and malignant lesions within this particular cohort. This underscores their high diagnostic significance.
Publication Details
Page(s) 1087-1092
Published Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 33, Issue: 10, Year: 2023

Request the full text from PASTIC

Keywords
Lung cancer, Postoperative, Benign lesions of lung, Arti cial intelligence, Quantitative parameters
0

Citations

0

Downloads

65

Views