No Detail Found!

Review of Key Performance Indicator in a Hematology Laboratory: A Preventable Source of Error

Author(s)
Shaheen Kouser Department of Pathology, Dr. Ishrat ul Ebad Khan Institute of Blood Diseases (DIEKIBD), Dow University of Health Science, Karachi, Pakistan.
Farah Fatima Abbas Department of Pathology, Dr. Ishrat ul Ebad Khan Institute of Blood Diseases (DIEKIBD), Dow University of Health Science, Karachi, Pakistan.
Nasar Ul Huda Department of Anatomy, Dow Medical College (DMC), Dow University of Health Science, Karachi, Pakistan.
Zaenal Abideen Pahore Department of Clinical Hematology and BMT, Dow University of Health Science, Karachi, Pakistan
Sana Khurram Department of Clinical Hematology and BMT, Dow University of Health Science, Karachi, Pakistan
Hina Qureshi King Salman Bin Abdul Aziz Medical City, Madinah Munawarah, KSA
Maria Majeed Department of Pathology, Dr. Ishrat ul Ebad Khan Institute of Blood Diseases (DIEKIBD), Dow University of Health Science, Karachi, Pakistan
Oneeba Akram Dow University of Health Sciences, Karachi, Pakistan.
Wania Rabbani Dow University of Health Sciences, Karachi, Pakistan.
Samra Hassan Dow University of Health Sciences, Karachi, Pakistan.
Maham Khan Dow University of Health Sciences, Karachi, Pakistan.
Abstract
To assess the key performance indicators and the laboratory errors in the hematology laboratory. METHODOLOGY: A cross-sectional study was conducted at the DDRRL Hematology laboratory from October 2021 to September 2022. Data from the blood bank and hematological laboratory were collected. The primary investigator managed every step of the data-gathering operation. All the tools required for the process were gathered and arranged on a tray or trolley to be safe, accessible, and readily visible. Sterile glass or plastic tubes with rubber covers were used for blood collection. The information acquired during the study was inserted into a computer using an Excel sheet. SPSS version 20 was used for the analysis. All samples from the hematology section of DDRRL were included in this study, while all error-free samples were excluded. RESULT: From July to December, 414,400 hematology request forms were collected from OPD, private wards, IPD and Emergency. Overall, 2376 (0.573%) hematology laboratory errors were detected, of which 419 were Pre-analytical errors, 122 were analytical, and 1834 were post-analytical errors. CONCLUSION: We can lower the errors' likelihood if we appropriately handle the pre-analytical variables. Additionally, care must be taken when training workers to minimize the possibility of mistakes.
Publication Details
Page(s) 44-49
Published Journal: Journal of Liaquat University of Medical and Health Sciences, Volume: 22, Issue: 1, Year: 2023

Request the full text from PASTIC

Keywords
Pre-analytical, Laboratory services, Laboratory testing, Laboratory errors, Post-analytical, Analytical
0

Citations

0

Downloads

124

Views