Effcacy of Endotracheal Tube Cu Modi cation in Preventing Ventilator-associated Pneumonia

Author(s)
Yanshuo Wu Department of Critical Care Medicine, The Fourth Hospital of Hebei Medical University,Hebei,China
Congcong Zhao Department of Critical Care Medicine, The Fourth Hospital of Hebei Medical University,Hebei,China
Meirong Sun Department of Critical Care Medicine, The Fourth Hospital of Hebei Medical University,Hebei,China
Jingjing Bu Department of Critical Care Medicine, The Fourth Hospital of Hebei Medical University,Hebei,China
Zhenjie Hu Department of Critical Care Medicine, The Fourth Hospital of Hebei Medical University,Hebei,China
Yanling Yin Department of Critical Care Medicine, The Fourth Hospital of Hebei Medical University,Hebei,China
Abstract
The aim of this study was to evaluate the e ect of modifying the cu on preventing ventilator-associated pneu (VAP). PubMed, Embase and Cochrane Library were systematically searched from inception to April 2022, for randomised controlled trials (RCTs) that compared the e ect of a new type of cu intubation with traditional cu intubation on VAP incidence and intensive-care unit (ICU) mortality in mechanically ventilated patients. Nine RCTs with 1937 patients were nally evaluated. The pooled results for the incidence of VAP showed that the modi ed cu signi cantly decreased the morbidity of VAP compared with the traditional cu (relative ratio (RR) = 0.73, 95% con dence interval (CI) 0.56 0.95, p = 0.02). The subgroup analysis revealed that polyurethane (PU) cu (RR = 0.82, 95% CI 0.46 1.48, p = 0.52), conical cu (RR = 0.97, 95% CI 0.73 1.28, p = 0.82) and PU-conical cu (RR = 1.36, 95% CI 0.85 2.18, p = 0.20) did not decrease the incidence of VAP. Moreover, the improved cu combined with subglottic secretion drainage (SSD) could signi cantly reduce the VAP incidence (RR = 0.58, 95% CI 0.44 0.77, p = 0.0001). In terms of ICU mortality, there was no statistically signi cant di erence (RR = 0.83, 95% CI 0.68 1.02, p = 0.0b8e)tween the two groups. The modi ed cu is superior to the traditional cu in VAP prevention. In particular, the modi ed cu combined with subglottic secretion drainage has more advantages.
Publication Details
Page(s) 1050-1057
Published Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 33, Issue: 9, Year: 2023

Request the full text from PASTIC

Keywords
Intensive care unit, Intubation, Meta-analysis, Ventilator-associated pneumonia, Endotracheal cu
0

Citations

0

Downloads

64

Views