No Detail Found!

Comparison between two types of matrix systems for contact tightness in class-ii composite restorations

Author(s)
Muhammad Asif Operative Dentistry, Rehamat Memorial Hospital,Abbottabad, Pakistan
Imran Khattak Oral Biology, Peshawar Dental College,Peshawar, Pakistan
Asim Qureshi Operative Dentistry and Endodontics, Ayub Dental Section,Abbottabad, Pakistan
Muhammad Zain Operative dentistry and Endodontics, Peshawar Dental College,Peshawar, Pakistan
Naveed Aslam Operative Dentistry, Rehamat Memorial Hospital,Abbottabad, Pakistan
Muhammad Izaz Khan Bacha Khan College of Dentistry,Mardan-,Pakistan
Abstract
Background: The reconstruction of proximal defects with tight contacts has always been a challenge for dental clinicians, especially with composite material. Recent literature shows that the most frequently used matrix systems for the restoration of proximal cavities are circumferential or sectional matrix band systems. The objective of this study was to compare the contact tightness that is achieved with these two matrix band systems when using composite material. Methods: A total of 30 patients, i.e., 60 cavities were selected in this quasi-experimental study. Patients with two cavities in the posterior teeth were selected. Both the cavities were restored with the circumferential system, i.e., Tofflemire and sectional matrix band system, i.e., Palodent plus on the same appointment. Hence both systems were used in every patient and then contact tightness assess was ed based on an evaluation criterion, i.e., Fédération Dentaire Internationale clinical criteria for evaluation of contact in direct and indirect restorations. To make a comparison between the two systems Chi square test was used and p<0.05. Results: The mean age of the patients in the study was 31 years (SD, 7.59 years) with a range from 18 to 45 years. Most of the contact tightness in the Palodent matrix system was score 1 (n=33, 55%) and score 2 (n=17, 28.3%) while in Tofflemire was score 4 (n=28, 46.7%) and score 5 (n=19, 31.7%). Statistical analysis showed significance (p=.037) between Palodent matrix system contact tightness and Tofflemire. Conclusion: The sectional matrix band system was statistically superior to the circumferential matrix band system in achieving a tighter contact for class II composite restorations
Publication Details
Page(s) 253-258
Published Journal: Journal of Ayub Medical College, Volume: 35, Issue: 2, Year: 2023

Request the full text from PASTIC

Keywords
composite, Matrix system, Restorations
0

Citations

0

Downloads

52

Views