No Detail Found!

Comparative analysis of Shear Wave Elastography with serological indices for diagnosis of liver fibrosis in a tertiary care hospital in Pakistan

Author(s)
Kaukab Naeem Syed Department of Radiology, Quaid e Azam International Hospital,Islamabad.,Pakistan
Ambreen Zahoor Department of Radiology, Al Razi Hospital Lahore,,Pakistan
Yasir Abbas Department of Gastroenterology and Hepatology, Quaid e Azam International Hospital, Islamabad, Pakistan
Syed Hammad Wajid Talha Shah Department of Hepatology and Liver Transplantation, Quaid e Azam International Hospital, Islamabad, Pakistan
Iram Iqbal Department of Radiology, HBS Medical and Dental College,,Pakistan
Zara Sohail Department of Medicine, Quaid e Azam International Hospital,Islamabad,Pakistan
Waleed Bin Waris Department of Medicine, Quaid e Azam International Hospital,Islamabad,Pakistan
Ahsen Farooq Department of Radiology, Quaid e Azam International Hospital,Islamabad.,Pakistan
Amjad Salamat Department of Gastroenterology and Hepatology, Quaid e Azam International Hospital, Islamabad, Pakistan
Abstract
Hepatic parenchyma disorders are prevalent in contemporary life. These illnesses include chronic liver disease and liver fibrosis etc. Shear Wave Elastography is a novel technique that was created based on the application of shear waves and is used for diagnosis of these diseases. Serum-based biomarkers i.e., APRI and Fib-4 have been extensively researched and are established in clinical practice. This study aims to assess the diagnostic efficiency of SWE with APRI and FIB-4, in identifying the degree of liver fibrosis. Study Design: Retrospective Cross-Sectional Study This study was conducted at the Radiology Department of Quaid e Azam International Hospital, Islamabad from 01st March 2022 to 01st March 2023. A total of 60 patients were enrolled in this study. Fibrosis was defined on SWE. The serum concentrations of APRI and Fib-4 were noted. Data was analyzed in SPSS version 26.The mean age of the patients enrolled in the study was 44.050 ± 14.65 (p<0.001). The area under the curve (AUC) for SWE as compared to APRI was 0.772 and as compared to FIB-4 was 0.741. The sensitivity and specificity as compared to APRI was 64.4% and 80% respectively and as compared to FIB-4 was 69.2% and this 76.2%.The diagnostic accuracy of SWE was comparable to FIB-4 and APRI. The sensitivity, specificity and AUC value of SWE was quite similar to values of FIB-4 and APRI in reported literature. Therefore, SWE can serve as a suitable alternative for liver fibrosis detection and classification.
Publication Details
Page(s) 814-818
DOI DOI not available
Published Journal: Bioscience Research, Volume: 20, Issue: 3, Year: 2023

Request the full text from PASTIC

Keywords
Cirrhosis, APRI, FIB-4, Hepatic parenchymal disorders
0

Citations

0

Downloads

70

Views