No Detail Found!

Computed tomography of the chest: an evaluation of lung dose and radiogenic cancer risk using multidetector and single computed tomography scanners

Author(s)
Laith Khaled Albadarneh School of Physics, Universiti Sains Malaysia,11800 USM Minden, Penang,Malaysia
Azhar Abdul Rahman School of Physics, Universiti Sains Malaysia,11800 USM Minden, Penang,Malaysia
Haytham Ahmad ALEwaidat Department of Allied Medical Sciences-Radiology Technology, Faculty of Applied Medical Sciences, Jordan University of Science and Technology,Irbid 22110,Jordan
Qurain Turki Alshammari Diagnostic Radiology Department, College of Applied Medical Sciences, The University of Hail,Hail,Saudi Arabia
Abstract
Lung cancer is the second most frequently diagnosed cancer and the major cause of cancer-related mortality in the United States. This study aims to evaluate the patient radiation dosage for adult patients who underwent chest CT scans using single-slice and multi-detector scanners in north of Jordan. Also, this study aimed to evaluate the potential risks associated with exposure to ionizing radiation during chest CT scans and to compare these risks between single and multidetector CT scanners. Computed Tomography dosage reports were obtained for 604 participants they had CT chest using single slice and multidetector scanners. Effective doses were estimated by multiplying the DLP values by tissueweighted factors. The average weighted effective dose received by the lung was multiplied by the standard National Academy of Sciences Biologic Effects of Ionizing Radiation BEIR VII conversion factor in order to determine the incidence of lung cancer from a CT chest examination. The average effective dose to the chest from single, 16-slice, and 64-slice scanners was 2.99 mSv, 8.61 mSv, and 9.45 mSv, respectively. From single, 16-slice, and 64-slice scanners, the lung received equivalent doses was 4.5, 11.96, and 13.13 mSv from CT chest procedures. Females had a higher incidence of lung cancer than males. Cancer occurs at a rate of 5 to 13 per 100,000 CT chest examinations in males (=18 years) and (11 to 31) per 100,000 CT chest examinations in females (=18 years). According to the findings, females who have CT scans are more likely than male to develop lung cancer. The reasons for CT procedures must be strengthened, particularly for female patients. Single-slice scanners gave lower radiation doses than multidetector scanners, but the image quality was unacceptable; consequently, multidetector scanners are suggested for CT chest examinations, and chest protocols for 64-slice scanners should be evaluated to reduce patient radiation exposure. This study aim to awareness of radiation risks and optimizing imaging protocols also, this study allow patients to make informed decisions about their medical care and understand the importance of following recommended imaging protocols. This study suggests the establishment of diagnostic reference levels and criteria for justification and optimization (DRLs).
Publication Details
Page(s) 492-497
DOI DOI not available
Published Journal: Bioscience Research, Volume: 20, Issue: 2, Year: 2023

Request the full text from PASTIC

Keywords
Lung Cancer, Computed Tomography (CT), Dose length product (DLP), Multi-detector CT, Diagnostic Reference Level (DRLs)
0

Citations

0

Downloads

65

Views