No Detail Found!

Computed tomography of the abdomen: an evaluation of the effective radiation dose and incidence of radiogenic colon cancer in north of Jordan

Author(s)
Laith Albadarneh School of physics, Universiti Sains Malaysia,11800 USM Minden Penang, Malaysia
Azhar Abdul Rahman School of physics, Universiti Sains Malaysia,11800 USM Minden Penang, Malaysia
Haytham Ahmad AL Ewaidat Department of Allied Medical Sciences-Radiology Technology, Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid 22110, Jordan
Marwan Alshipli Medical Imaging and Radiography Department, Aqaba University of Technology, Aqaba, Jordan
Hamad Yahia Abu Mhanna School of physics, Universiti Sains Malaysia,11800 USM Minden Penang, Malaysia
Thair Hussein Khazaalah School of physics, Universiti Sains Malaysia,11800 USM Minden Penang, Malaysia
Ghassan Almurshedi School of physics, Universiti Sains Malaysia,11800 USM Minden Penang, Malaysia
Abdallah Alsaid School of physics, Universiti Sains Malaysia,11800 USM Minden Penang, Malaysia
Esraa Abu Lubad Department of Allied Medical Sciences-Radiology Technology, Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid 22110, Jordan
Qurain Turki Alshammari Diagnostic Radiology Department, College of Applied Medical Sciences, University of Hail, Hail, Saudi Arabia
Abstract
Computed Tomography (CT) is a widely used imaging modality that plays an essential role in the diagnosis and management of various diseases. However, CT scans expose patients to ionizing radiation, which can have long-term health risks, including the development of radiogenic cancer. Therefore, it is crucial to evaluate the effective radiation dose and incidence of radiogenic colon cancer in patients undergoing CT of the abdomen in the North of Jordan. This study aimed to evaluate the effective radiation dose and incidence of radiogenic colon cancer in patients underwent CT of the abdomen in the North of Jordan. A total of 1505 patients were included in the study, and their CT scans were analyzed to estimate the effective radiation dose. The incidence of radiogenic colon cancer was also evaluated in this population using a retrospective cohort study design. The results of this study indicate that the average effective radiation dose for CT of the abdomen in the North of Jordan were (12.75 mGy), (13.22 mGy), m ale and female, respectively, which is within the recommended range. Furthermore, the incidence of radiogenic colon cancer was 0.0107% and 0.0073% male and female respectively, which is relatively low compared to other studies. These findings suggest that the use of CT scans in the North of Jordan is relatively safe in terms of the effective radiation dose and the incidence of radiogenic colon cancer. However, it is important to note that despite the low incidence of radiogenic colon cancer in this study, the potential long-term risks associated with radiation exposure should not be overlooked. Therefore, it is recommended to optimize the radiation doses in CT scans and to continually monitor the potential longterm risks associated with radiation exposure. In conclusion, this study provides valuable insights into the effective radiation dose and incidence of radiogenic colon cancer in patients undergoing CT of the abdomen in the North of Jordan. These findings can help healthcare providers and policymakers make informed decisions regarding the use of CT scans in this region and highlight the importance of optimizing radiation doses to minimize potential long-term risks associated with radiation exposure. Also, this study recommends the establishment of criteria for justification and optimization, along with Diagnostic Reference Levels (DRLs).
Publication Details
Page(s) 245-250
DOI DOI not available
Published Journal: Bioscience Research, Volume: 20, Issue: 1, Year: 2023

Request the full text from PASTIC

Keywords
Multi-detector CT, Computed Tomography (CT), Dose length product (DLP), volume CT dose index (CTDIvol), Diagnostic Reference Levels (DRLs)
0

Citations

0

Downloads

82

Views