No Detail Found!

Intrarater reliability of cervical range of motion device among adults with and without chronic non-specific neck pain

Author(s)
Saeed Akhter Department of Physiotherapy, Sindh Institute of Physical Medicine and Rehabilitation, Karachi, Pakistan
Hamayun Zafar University, Institute, Clinics & Centre of Research in Physical Therapy, University of Lahore, Pakistan; University, Institute, Clinics & Centre of Research in Physical Therapy, University of Lahore, Lahore, Pakistan
Ashfaq Ahmad University, Institute, Clinics & Centre of Research in Physical Therapy, University of Lahore, Pakistan; University, Institute, Clinics & Centre of Research in Physical Therapy, University of Lahore, Lahore, Pakistan
Waqas Ahmed Farooqui School of Public Health, Dow University of Health Sciences, Karachi, Pakistan.
Abstract
Objective:To evaluate the intrarater reliability of the cervical range of motion device among adults with and without chronic non-specicfi neck pain. Method: The analytical, cross-sectional study was conducted from January to March 2019 at the Sindh Institute of Physical Medicine and Rehabilitation, Karachi, and comprised healthy adults with no neck pain in the preceding 6 months in Group A, and adults of either gender with chronic non-specicfi neck pain for >3 months in Group B. The two groups were further divided into age groups 21-30 years, 31-40 years and 41-50 years. A cervical range of motion device was used to measure the range of eflxion, extension, right and lef t lateral eflxion and right and left rotation of all the subjects. The measurements were taken by a single tester on day-1 and day-3 to assess the intrarater reliability. Data was analysed using SPSS 26. Results: Of the 60 subjects, there were 30(50%) in each of the two groups. Within the groups, there were 10(33.3%) subjects in each of the 3 age subgroups. Overall, there were 27(45%) males and 33(55%) females. In Group A, the intraclass correlation coecfiient values for all cervical ranges were between 0.81 and 0.99, whereas in Group B, the values ranged from 0.64 to 0.88. The intraclass correlation coecfiient values yielded good to ex cellent agreement in both groups (>0.75) except for left lateral eflxion in Group B (p=0.64), and all the values were statistically signicfiant (p<0.05). Conclusion: There was good to excellent intrarater reliability of cervical range of motion device in adults with and without chronic non-specicfi neck pain.
Publication Details
Page(s) 2017-2022
Published Journal: Journal of Pakistan Medical Association, Volume: 73, Issue: 10, Year: 2023

Request the full text from PASTIC

Keywords
Reliability, Range of motion, Non-specific neck pain., Spinal column
0

Citations

0

Downloads

59

Views