No Detail Found!

Comparison of cannulated screw combined with medial femoral plate and simple cannulated screw in the treatment of pauwels type iii femoral neck fracture: a meta-analysis with trial sequential analysis

Author(s)
Ming Li Department of Orthopedic Trauma, Honghui Hospital, Xi an Jiaotong University,Xi an, Shaanxi,China
Cheng Ren Department of Orthopedic Trauma, Honghui Hospital, Xi an Jiaotong University,Xi an, Shaanxi,China
Teng Ma Department of Orthopedic Trauma, Honghui Hospital, Xi an Jiaotong University,Xi an, Shaanxi,China
Zhong Li Department of Orthopedic Trauma, Honghui Hospital, Xi an Jiaotong University,Xi an, Shaanxi,China
Yibo Xu Department of Orthopedic Trauma, Honghui Hospital, Xi an Jiaotong University,Xi an, Shaanxi,China
Liang Sun Department of Orthopedic Trauma, Honghui Hospital, Xi an Jiaotong University,Xi an, Shaanxi,China
Yao Lu Department of Orthopedic Trauma, Honghui Hospital, Xi an Jiaotong University,Xi an, Shaanxi,China
Qian Wang Department of Orthopedic Trauma, Honghui Hospital, Xi an Jiaotong University,Xi an, Shaanxi,China
Hanzhong Xue Department of Orthopedic Trauma, Honghui Hospital, Xi an Jiaotong University,Xi an, Shaanxi,China
Qiang Huang Department of Orthopedic Trauma, Honghui Hospital, Xi an Jiaotong University,Xi an, Shaanxi,China
Kun Zhang Department of Orthopedic Trauma, Honghui Hospital, Xi an Jiaotong University,Xi an, Shaanxi,China
Abstract
This study aimed to compare the e cacy of cannulated screw combined with medial femoral plate and simple cannulated screw for Pauwels type III femoral neck fracture. In May 2022, relavent clinical trial articles were searched in seven online databases. After literature screening, quality evaluation, and data extraction according to the speci c inclusion and exclusion criteria, the di erences in therapeutic e cacy, complications, and intraoperative outcomes were compared between the two groups. A total of nine articles were nally included in the meta-analysis. The qualities of the nine articles were medium. Although the results showed that cannulated screw combined with medial femoral plate prolonged the operation time and increased blood loss (p <0.05), it demonstrated better fracture reduction and Harris score, shorter healing time and less internal xation failure than in the simple cannulated screw in the treatment of Pauwels type III fracture (p <0.05). The sensitivity analysis, Egger s test, and trial sequential analysis (TSA) showed that the combination results were stable and reliable. This demonstrated that compared to that with the simple cannulated screw, the cannulated screw combined with medial femoral plate had better e cacy and less complication.
Publication Details
Page(s) 792-798
Published Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 33, Issue: 7, Year: 2023

Request the full text from PASTIC

Keywords
Medial femoral plate, Trial sequential analysis, Femoral neck fracture, Therapy e ect, Cannulated screw
0

Citations

0

Downloads

67

Views