Diagnostic accuracy of plain computed tomography in detecting acute cerebral venous sinus thrombosis keeping magnetic resonance venography as gold standard

Author(s)
Ayesha Tanveer Department of Radiology, Combined Military Hospital, Rawalpindi, Pakistan.
Koukab Javed Department of Radiology, Combined Military Hospital, Rawalpindi, Pakistan.
Muhammad Zain Arshad Department of Radiology, Combined Military Hospital, Rawalpindi, Pakistan.
Yumna Rubab Department of Radiology, Combined Military Hospital, Rawalpindi, Pakistan.
Sabahat Tanveer Department of Radiology, Combined Military Hospital, Rawalpindi, Pakistan.
Hazfi Zulqarnain Department of Radiology, Combined Military Hospital, Rawalpindi, Pakistan.
Abstract
Objective: To determine the diagnostic accuracy of plain computed tomography using the ratio between hounsefild unit and haematocrit of cerebral venous sinuses in cases of acute cerebral venous sinus thrombosis taking magnetic resonance venography as the gold standard. Method: The cross-sectional validation study was conducted at the Department of Diagnostic Radiology, Combined Military Hospital, Rawalpindi, Pakistan, from March 9 to September 8, 2021, and comprised patients regardless of age and gender presenting with acute neurological and visual signs and symptoms of cerebral venous sinus thrombosis for <5 days. The patients were brain-imaged on 128-slice computed tomography scanner, and the image was assessed and the attenuation values in terms of Hounsefild unit of dural venous sinuses were calculated by taking appropriate region of interest. Haemoglobin and haematocrit values were noted from blood reports, and then the ratio between Hounsefild unit and haematocrit ratio was calculated. Magnetic resonance venography of the patients were performed and the patients were assessed for dural venous thrombosis. Data was analysed using SPSS 23. Results: Of the 201 patients, 98(48.8%) were males and 103(51.2%) were female. The overall mean age was 35.32±19.707 years (range: 1 month-70 years). According to the Hounsefild unit-haematocrit ratio, acute cerebral venous sinus thrombosis was detected in 173(86.01%) patients, while magnetic resonance venography detected 178(88.6%). The Hounsefild unithaematocrit ratio had sensitivity 91.01%, specicfiity 52.17% and diagnostic accuracy 86.57%. Conclusion: Computed tomography attenuation value and Hounsefild unit-haematocrit ratio on unenhanced computed tomography could be used as a reliable method to detect acute cerebral venous sinus thrombosis in emergency settings.
Publication Details
Page(s) 830-833
Published Journal: Journal of Pakistan Medical Association, Volume: 73, Issue: 4, Year: 2023

Request the full text from PASTIC

Keywords
Computed tomography, Magnetic resonance venography., Acute cerebral venous sinus thrombosis
0

Citations

0

Downloads

80

Views