No Detail Found!

Electrochemical sensing of luteolin from straw pyrolysis carbon prepared by molten salt carbonization

Author(s)
Youluan Lu Hubei Key Laboratory of Biologic Resources Protection and Utilization, Hubei Minzu University, Enshi, China. School Of Chemical and Environmental Enigineering, Hubei Minzu University, Enshi, China.
Xinwei Mu Hubei Key Laboratory of Biologic Resources Protection and Utilization, Hubei Minzu University, Enshi, China. School Of Chemical and Environmental Enigineering, Hubei Minzu University, Enshi, China.
Yaopeng Liu Hubei Key Laboratory of Biologic Resources Protection and Utilization, Hubei Minzu University, Enshi, China. School Of Chemical and Environmental Enigineering, Hubei Minzu University, Enshi, China.
Zhen Shi School Of Chemical and Environmental Enigineering, Hubei Minzu University, Enshi, China.
Yin Zheng Hubei Key Laboratory of Biologic Resources Protection and Utilization, Hubei Minzu University, Enshi, China. School Of Chemical and Environmental Enigineering, Hubei Minzu University, Enshi, China.
Wensheng Huang School Of Chemical and Environmental Enigineering, Hubei Minzu University, Enshi, China.
Fangming Lou School Of Chemical and Environmental Enigineering, Hubei Minzu University, Enshi, China.
Abstract
Summary: In order to well use waste biomass and realise the quantitative analysis of luteolin, the sorghum straw from the old broom was used to prepare biomass carbon material (CMS-PCSS) through the molten salt carbonization. Then the CMS-PCSS was characterised by scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) Raman spectra (Raman), and N2 sorption analysis. In addition, the electrochemical performance of the CMS-PCSS based sensors was examined by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). Under the first-rank experimental conditions, the electrochemical sensor established with this material performed well in the quantitative analysis and actual sample detection of luteolin, the detection range of luteolin was 0.05~10.0 µmol/L, and the actual achievable minimum detection limit was 0.019 µmol/L.
Publication Details
Page(s) 587-595
DOI DOI not available
Published Journal: Journal of Chemical Society of Pakistan, Volume: 44, Issue: 6, Year: 2022

Request the full text from PASTIC

Keywords
Luteolin, Electrochemical sensor, Analytical chemistry, Molten salt carbonization, Biomass pyrolytic carbon
0

Citations

0

Downloads

58

Views