No Detail Found!

Accuracy of Ultrasound for Determination of Fetal Gender

Author(s)
ANEK AMMAR Department of Radiology, CMH Lahore, Pakistan
MUHAMMAD ALI ZUL HUSNAIN Department of Radiology, CMH Lahore,Pakistan
MUHAMMAD ARSHAD Avicenna Medical College CMH Lahore, Pakistan
TARIQ MEHMOOD MIRZA CMH Lahore Medical College, Pakistan
ZIMAR ARSHAD Niazi Medical College, Sargodha, Pakistan
TALIA ARSHAD Niazi Medical College,Sargodha,Pakistan
DAROOJ ARSHAD de'Montmorency College of Dentistry,Lahore,Pakistan
MUAZ AMJAD RHC Moazamabad,Pakistan
Abstract
Aim: To evaluate the accuracy of ultrasound in determining the phenotypic foetal gender in all three trimesters. Study design: Cross sectional study. Place and duration of study: Department of Diagnostic Radiology Combined Military Hospital Lahore from 1st January 2020 to 30th April 2020. Methodology: Three hundred and seventy two patients in the inclusion criteria were selected. Ages of patients, gestational ages of foetuses and their genders were determined according to the ultrasonographic signs using ultrasound examination. Patients were contacted 3 weeks after the estimated date of delivery and phenotypic sex recorded. Results: Mean age was 34 years. Median gestational age was 21 weeks 3 days. Accuracy of gender determination by ultrasound in 1st, 2nd and 3rd trimesters was 62%, 97% and 95% respectively. Sensitivity and specificity of ultrasound in 1st trimester for males are 66% and 72%; and for females are 72% and 66% respectively. Positive and negative predictive values for male are 69% and 71%; and for female are 71% and 69% respectively. Sensitivity and specificity of ultrasound in 2nd trimester for males are 95% and 100%; and for females are 100% and 95% respectively. Positive and negative predictive values for male are 100% and 94%; and for female are 94% and 100% respectively. Sensitivity and specificity of ultrasound in 3rd trimester for males are 94% and 96%; and for females are 96% and 94% respectively. Positive and negative predictive values for male are 97% and 93%; and for female are 93% and 97% respectively. Conclusion: There is a high accuracy of ultrasound in determination of fetal gender in second and third trimesters.
Publication Details
Page(s) 1237-1239
Published Journal: Pakistan Journal of Medical and Health Sciences, Volume: 15, Issue: 6, Year: 2021

Request the full text from PASTIC

Keywords
Ultrasound, sensitivity, gender, Predictive value, Specificity, trimester
0

Citations

0

Downloads

214

Views