No Detail Found!

Integrity & functional outcome after massive rotator cuff repair in double row repair manner: a prospective study.

Author(s)
Arsalan Ahmed Abro Department Orthopaedic, K-Block, Liaquat National Hospital, Karachi, Pakistan
Muhammad Sufyan Department Orthopaedic, K-Block, Liaquat National Hospital, Karachi, Pakistan
Matiullah Shah Liaquat National Hospital, Karachi, Pakistan.
Muhammad Mairaj Khan Department Fazaia Ruth Pfau Medical College, Faisal Hospital,Base Faisal, Shah Rah e Faisal, Karachi, Pakistan.
Kazim Rahim Najjad Liaquat National Hospital, Karachi, Pakistan
Syed Kamran Ali Shah Department Fazaia Ruth Pfau Medical College, Faisal Hospital,Base Faisal, Shah Rah e Faisal, Karachi, Pakistan
Hifza Bashir Department Fazaia Ruth Pfau Medical College, Faisal Hospital,Base Faisal, Shah Rah e Faisal, Karachi, Pakistan.
Abstract
Objective: To assess the efficacy of shoulder cuff restoration by means of arthroscopic repair in dual row repair fashion and demonstrate 30 months practical result using a scoring system based on modified American Shoulder & Elbow Score System (ASES) Materials And Methods: This is a descriptive cross-sectional study and includes 23 patients who underwent repair of massive rotator cuff tears in double row manner arthroscopically. Study was carried out at Liaquat National Hospital during January 2018 June 2019 at orthopedics department. The clinical evaluation was done by the operative surgeon on the patients reported for surgery in outpatient department pre-operatively and then at follow up postoperatively at 6 weeks, 3 months, 6 months ,1 year and final evaluation done on average of 30 months. Preoperative and postoperative functional evaluation done and compared by assessing the function on basis of a scoring system based on modified ASES score Results: The average functional outcome scores based on Patient Self Assessed Questionnaire improved significantly at the time of the final follow-up (p < 0.01). 12 months postoperatively, repair integrity was assessed by magnetic resonance imaging, which revealed that 16 patients had a type-I repair; 2 patients had a type II repair, while only 1 patient had type III repair. As per this study Re tear rate was 5% for large and massive tears. The shoulders with a type-III repair demonstrated significantly inferior functional outcome in terms of overall scores and strength compared with the other types of repairs (p< 0.01). Conclusion: In this study, we found arthroscopic double row repair technique is an effective procedure in terms of massive rotator cuff tears repair with very little risk of re-tear and significant improvement in functional activities.
Publication Details
Page(s) 22-27
DOI DOI not available
Published Journal: Journal of Pakistan Orthopedic Association, Volume: 35, Issue: 1, Year: 2023

Request the full text from PASTIC

Keywords
Rotator cuff repair, Modified American shoulder and elbow score
0

Citations

0

Downloads

32

Views