Reliability of modified-modified Schober's test for the assessment of lumbar range of motion

Author(s)
Fareeha Amjad University Institute of Physical Therapy, The University of Lahore,Lahore,Pakistan
Mohammad Ali Mohseni Bandpei University Institute of Physical Therapy, The University of Lahore,Lahore,Pakistan
Syed Amir Gilani University Institute of Physical Therapy, The University of Lahore,Lahore,Pakistan
Ayesha Arooj University Institute of Physical Therapy, The University of Lahore,Lahore,Pakistan
Abstract
Objective: To determine the intra-rater reliability of modifi ed-modifi ed Schober's test for measuring lumbar fl exion and extension in patients of lumbar radiculopathy. Method: The case-control reliability study was conducted at the University of Lahore Teaching Hospital, Lahore, Pakistan, from March to September 2020, and comprised lumbar radiculopathy patients of either gender aged 35-60 years in group A and healthy controls in group B. Lumbar fl exion and extension were measured by the same examiner on three different occasions. A non-stretching measuring tape was used in which the fi rst two measurements were taken using the modifi edmodifi ed Schober's test on the same day with a difference of 5 minutes, and the third measurement was taken three days later to assess reliability. To assess the test-retest reliability, intraclass correlation coefficient was calculated through twoway random analysis of variance. Standard error of measurement and minimal detectable change were also calculated. Data was analysed using SPSS 25. Results: Of the 40 subjects, 20(50%) were in group A with a mean age of 45.00±6.72 years, and 20(50%) were in group B with a mean age of 49.60±6.65 years. Overall, there were 16(40%) male and 24(60%) female subjects. Within-day lumbar lf exion and extension measurements were highly reliable in controls (intraclass correlation coefficient 0.93 for fl exion and 0.96 for extension) as well as in patients (intraclass correlation coefficient 0.94 for fl exion and 0.95 for extension). The high values of intraclass correlation coefficient 0.91 for fl exion and 0.94 for extension in the controls and 0.83 for fl exion and 0.92 for extension in the patients showed high reliability also for between-days measurements. Conclusion: The modifi ed-modifi ed Schober's test appeared to be a highly reliable technique for the measurement of lumbar fl exion and extension in patients of lumbar radiculopathy as well as in healthy controls.
Publication Details
Page(s) 1755-1759
DOI DOI not available
Published Journal: Journal of Pakistan Medical Association, Volume: 72, Issue: 9, Year: 2022

Request the full text from PASTIC

Keywords
Lumbar radiculopathy, Lumbar range of motion., Modified-Modified Schober’s test