No Detail Found!

Comparison the outcome of dynamic compression plating with interlocking nail procedure in patients with fracture shaft of humerus

Author(s)
Muhammed Bakhsh Shahwani Bolan Medical College Quetta, Pakistan
Tariq Hasni Bolan Medical College Quetta, Pakistan
Wazir Ahmed Bolan Medical College Quetta, Pakistan
Abstract
Aim: To examine the outcomes of dynamic compression plating and interlocking nail procedure in patients presented with fracture shaft of humerus. Study Design: Prospective study Place and Duration of Study: Department of Orthopedic Surgery, Bolan Medical Complex Hospital Quetta from 1st January 2018 to 31st December 2018. Methodology: Forty four patients of both genders with ages 20 to 60 years presented with fracture shaft of humerus were included in this study. Patients were divided into two Groups Group I contain 22 patients and received dynamic compression plating and Group II contains 22 patients and received interlocking nail treatment. Pre and post-operative radiographical assessment was done. Post-operative complications were noted at 12 day. Functional outcomes were examined by the NEERs criteria. Results: Thirty two (72.73%) patients (17 Group I, 15 Group II) were males and 12 (27.27%) patients (5 Group I, 7 Group II) were females. RTA was the most common mode of injury in 28 (63.64%) patients. Most of the fractures were on right side 30 (68.18%). Transverse fracture was the most common type found in 28 (63.64%) patients. Middle third was the most common level of fracture found in 25 (56.82%) patients. According to the NEER criteria, 81.82% patients shows excellent, 4 patients shows satisfactory with no poor results in Group I and in Group II 5 (22.73%) patients shows excellent, 12 (54.55%) patients shows satisfactory results and 5 (22.73%) shows unsatisfactory results. Conclusion: It is concluded that dynamic compression plating shows better outcomes with less rate of complications as compared to interlocking nail procedure.
Publication Details
Page(s) 1149-1151
DOI DOI not available
Published Journal: Pakistan Journal of Medical and Health Sciences, Volume: 14, Issue: 4, Year: 2020

Request the full text from PASTIC

Keywords
Dynamic compression plating, Interlocking Nail, Fracture shaft of humerus
0

Citations

0

Downloads

53

Views