No Detail Found!

Comparison of a cellphone-based fundoscope with traditional handheld direct fundoscope for checking red reflex in neonates

Author(s)
Muhammad Tauseef Omer Department of Paediatric Medicine and Neonatology, Services Institute of Medical Sciences, Services Hospital, Lahore, Pakistan
Amna Rashid Butt Department of Paediatric Medicine and Neonatology, Services Institute of Medical Sciences, Services Hospital, Lahore, Pakistan
Tayyaba Khawar Butt Department of Paediatric Medicine and Neonatology, Services Institute of Medical Sciences, Services Hospital, Lahore, Pakistan
Muhammad Asif Siddiqui Department of Paediatric Medicine and Neonatology, Services Institute of Medical Sciences, Services Hospital, Lahore, Pakistan
Saba Bakht Department of Paediatric Medicine and Neonatology, Services Institute of Medical Sciences, Services Hospital, Lahore, Pakistan
Sulman Javaid Department of Neonatology, Children Hospital, Faisalabad, Pakistan
Abstract
Background: Traditional handheld fundoscopes are expensive instruments and require training and expertise for their use to check red reflex in neonates. Cellphone based fundoscopes may prove to be a cheaper alternative to check red reflex for screening of congenital cataracts in neonates. Objective: Evaluation of the diagnostic accuracy of a cellphone-based fundoscope OptiCard for screening of cataracts in neonates by checking pupillary red reflex. Methods: An instrument validation study was conducted in the Neonatology Department of Services Hospital Lahore for 3 months from 1st August to 30th October 2021 to assess the diagnostic accuracy of cellphone-based fundoscope OptiCard for screening of cataracts in neonates using Wilson Score. Results: Eyes of 110 neonates were examined for red reflex. Cellphone-based fundoscope OptiCard was found to have a sensitivity of 100% for diagnosing abnormal red reflex while its specificity was found to be 99.06% as compared to the traditional handheld direct fundoscope. Conclusion: Cellphone-based fundoscope OptiCard has good diagnostic accuracy for detecting abnormal red reflex and it allows the images of pupillary glow to be stored for a photo follow-up.
Publication Details
Page(s) 354-359
DOI DOI not available
Published Journal: Annals of King Edward Medical University, Volume: 28, Issue: SI, Year: 2022

Request the full text from PASTIC

Keywords
cataract screening, cellphone-based fundoscopy, red reflex screening, Red reflex, direct fundoscopy
0

Citations

0

Downloads

123

Views