No Detail Found!

Comparative study of hemodialysis in arteriovenous fistulas in low versus high blood flow rate

Author(s)
Sultan Abdulwadoud Alshoabi Department of Diagnostic Radiology Technology, College of Applied Medical Sciences, Taibah University, Almadinah Almunawwarah,Kingdom of Saudi Arabia
Ali Twyla Almutairi Department of Radiology, King Fahad Hospital, Almadinah Almunawwarah, Kingdom of Saudi Arabia
Fahad H. Alhazmi Department of Diagnostic Radiology Technology, College of Applied Medical Sciences, Taibah University, Almadinah Almunawwarah, Kingdom of Saudi Arabia
Abdulaziz A. Qurashi Department of Diagnostic Radiology Technology, College of Applied Medical Sciences, Taibah University, Almadinah Almunawwarah,Kingdom of Saudi Arabia
Abdulrahman Saleh Alharbi Department of Radiology, King Fahad Hospital, Almadinah Almunawwarah, Kingdom of Saudi Arabia
Adel Faiz Alhejaili Department of Radiology, King Fahad Hospital, Almadinah Almunawwarah, Kingdom of Saudi Arabia
Abstract
Background and Objective: Arteriovenous Fistula (AVF) is an essential requirement in Hemodialysis (HD) to remove toxins and excess fluid from the blood of patients with Chronic Renal Failure (CRF). The Blood Flow Rate (BFR) in AVF is an important factor in the success of HD. Due to a lack of studies of low BFR during HD, this study was conducted. The objective of this study was to compare the success rate of HD in patients with a BFR = 400-500 mL minG1  (group-2), in comparison to those of higher BFR (group-1). Materials and Methods: This prospective cohort study was conducted at the ultrasound Doppler (USD) unit in King Fahad Hospital in Almadinah from July to December, 2019. In this study, 44 patients underwent AVF for HD and were assessed by USD for 2 consecutive visits at 3 months intervals. The success rate of HD was measured in patients with a BFR = 400-500 mL minG1  and in those with BFR>500 mL minG1 . A comparison of the success rate in the 2 groups was done. Results: Among the 44 patients, 59% were males and 41% were females. The age of participants ranged from 20-80 years (mean: 46.75±13.67 years). The patients underwent HD 3 or 2 session's weekG1  for 3 or 4 hrs (mean 3.84±0.36 h) per session. In the first assessment, the success rate was 100% in both groups but it was 88.24% in group-1 and 70% in group-2 in the second assessment. Conclusion: The success rate of hemodialysis in patients with BFR 400-500 mL minG1  in AVF was acceptable in comparison to that in patients with BFR>500 mL minG1..
Publication Details
Page(s) 66-71
Published Journal: Pakistan Journal of Biological Sciences, Volume: 24, Issue: 1, Year: 2021

Request the full text from PASTIC

Keywords
high blood flow rate, Arteriovenous fistula, Arteriovenous graft, Renal replacement therapy, low blood flow rate, hemodialysis success, Chronic Renal Failure
0

Citations

0

Downloads

107

Views