A study has been carried out to determine the optimum configuration of a multi floors building by changing shear wall location. Four different cases of shear wall location for a 25 floors building have been analyzed as a space frame system, using a standard package ETAB subjected to lateral and gravity loading in accordance with UBC provisions. It is found that columns and beams forces are found to increase on grids opposite to the changing position of shear wall away from the centroid of the building. Twisting moments in members are observed to show increasing trend with enhancement in the eccentricity between geometrical centroid of the building and shear wall position. Stresses in shear wall elements have more pronounced effect in elements parallel to displaced direction of shear wall as compared to those in perpendicular direction. The lateral displacements of the building is uniform for a zero eccentricity case. On the contrary, the drift is more on grids on one side than that of the others in case of eccentric shear wall position. It is concluded that the shear wall should be placed at a point by coinciding center of gravity and centroid of the building.