No Detail Found!

Highly Sensitive and Ultrafast Liquid Chromatography-tandem Mass Spectrometry Internal Standard Method for Determination of Alpha-Tocopherol in Serum and Application of Validated Method on Patient Serum Samples in Pakistan

Author(s)
Humera Sha Makhdoom Departments of Chemical Pathology and Toxicology, Chughtai Healthcare, Lahore, Pakistan
Mohammad Dilawar Khan Departments of Chemical Pathology and Toxicology, Chughtai Healthcare, Lahore, Pakistan
Omar Rasheed Chughtai Departments of Chemical Pathology and Toxicology, Chughtai Healthcare, Lahore, Pakistan
Zeerak Abbas Departments of Chemical Pathology and Toxicology, Chughtai Healthcare, Lahore, Pakistan
Areeba Azad Departments of Chemical Pathology and Toxicology, Chughtai Healthcare, Lahore, Pakistan
Hijab Batool Departments of Chemical Pathology and Toxicology, Chughtai Healthcare, Lahore, Pakistan
Abstract
Objective: To optimize and validate a speci c, sensitive and fast liquid Chromatography coupled to triple quadrupole Mass Spectrometric (LC-MS / MS) technique for accurate detection of serum ±-tocopherol (Vitamin E) levels. Study Design: An experimental based study. Place and Duration of Study: The Clinical and Forensic Toxicology section of Chughtai Lab, Jail Road Lahore, from April to September 2022. Methodology: Methanol was used to deproteinize serum samples. The chromatographic separation was achieved using an Agilent In nity-Lab Poroshell 120EC-C18 column, Agilent 6470 LC-MS/MS (equipped with an Electron Spray Ionization source) in gradient elution mode using 0.1% LCMS grade formic acid in water and LCMS-grade methanol as mobile phases. Hexa-deuterated ±-tocopherol was employed as internal standard to minimise matrix interferences. Results: The retention time of ±-tocopherol was 3.0 ± 0.1 minutes. The linear concentrations obtained were ranged from 0.05-2 mg/dL with e0.985% coe cient of linearity. Detection and lower quanti cation limits determined were 0.025mg/dL and 0.05mg/dL, respectively. Recovery ranged from 96.5 to 99.8% and ionization suppression was -15.2% and -15.9% at high and low concentrations of ±-tocopherol in serum. Intra-day and inter-day coe cient variation values were 4.2-4.9% and 5.0-5.9%, respectively. Conclusion: An e cient and reliable tandem mass spectrometric technique for vitamin E analysis in serum was optimized, validated, and applied to 80 patient samples. This method has usefulness in clinical application for the accurate determination of vitamin E without potential matrix interferences.
Publication Details
Page(s) 254-260
Published Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 33, Issue: 3, Year: 2023

Request the full text from PASTIC

Keywords
Vitamin E, LC-MS/MS, validation., tocopherol, Internal standard
0

Citations

0

Downloads

74