No Detail Found!

Is there a Correlation between Hepatic Venous Indices and Main Pulmonary Artery Diameter?

Author(s)
Taha Yasin Arslan Department of Radiology, School of Medicine, Balikesir University,Balikesir,Turkey
Erdogan Bulbul Department of Radiology, School of Medicine, Balikesir University,Balikesir,Turkey
Bahar Yanik Department of Radiology, School of Medicine, Balikesir University,Balikesir,Turkey
Gulen Demirpolat Department of Radiology, School of Medicine, Balikesir University,Balikesir,Turkey
Emrah Akay Department of Radiology, School of Medicine, Balikesir University,Balikesir,Turkey
Abstract
Objective: To search whether there is a correlation between middle hepatic venous indices (HVIs) obtained bypulsed waved doppler ultrasonography (PW-DUS) and the main pulmonary artery (mPA) diameter, calculated by computed tomography (CT). Study Design: A descriptive cross-sectional study. Place and Duration of Study: Department of Radiology, Balikesir University School of Medicine, Turkey, from February to December 2020. Methodology: After excluding the cases with suspected COVID-19 from the cases sent to the Radiology Department for chest CT exams with the mPA included in the cross-sections, the volunteers were evaluated with PW-DUS. The study group consisted of 66 cases. Two radiologists measured the velocity values of the A, S, and D waves in the recorded PW Doppler spectra. HVIs (A/S, A/S+D, A/A+S+D) were calculated. The mPA diameter was calculated in the axial plane from the pulmonary trunk, 1cm proximally to the bifurcation manually on the workstation. The correlation between the HIVs and mPA diameter was evaluated. Interoperator reliability was also analysed. Results: Thirty-nine males (59%) and 27 (41%) females were included in the study group. The mean HVI values were 0.50 ±0.20, 0.28 ±0.12, and 0.21 ±0.07 for A/S, A/A+S, and A/A+S+D, respectively. The mean mPA diameter was 24.0 ±3.3 mm. Correlation analysis determined that the HVIs were positively correlated with mPA diameter (r=0.730-0.765-0.751, p<0.001). Inter-observer correlation coe cients were found to be compatible between two radiologists. Conclusion: A signi cant and strong correlation was found between HVIs and mPA diameter. The mPA diameter that re ects the pulmonary artery systolic pressure (PAP) increased as the HVIs increased. Therefore, PW-DUS may be helpful to evaluate PAP as a quantitative method that is cost-e ective, easily accessible and radiation-free.
Publication Details
Page(s) 1529-1533
DOI DOI not available
Published Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 32, Issue: 12, Year: 2022

Request the full text from PASTIC

Keywords
Multidetector computed tomography, pulmonary hypertension, Hepatic veins, Pulsed doppler ultrasonography, Pulmonary artery
0

Citations

0

Downloads

78

Views