In the construction world, concrete is the most widely used material because of its reliable maintenance and usage along with high fire and water resistivity. However, the major drawback of using concrete is its inefficiency of healing cracks, fishers automatically that typically arises due to lower tensile strength of material as well as due to erosion, salling and popouts etc. The present work targeted to investigate the parameters like compressive strength of bioconcrete, its flexural strength and pullout strength. We used Bacillus clausii, Bacillus coagulans and Lactobacillus reuteri for our study. The results show higher compressive strength (31.85 %, 37.08 %) of bio-concrete when Bacillus coagulans used and tested at 7 and 28 days; higher flexural strength (22.6 %, 23.0 %) in the presence of Bacillus coagulans and Bacillus clausii after 7 and 28 days of curing while higher pullout strength (51.26 %, 38.25 %) when bio-concrete was incorporated by Lactobacillus reuteri. It may be concluded that the use of bacterial strains in the concrete will be advantageous in reducing porosity, reinforcement bar corrosion as well as sealing of cracks to increase service life of structure. It will also improve compressibility and tensile strength to make it a life enriching and elegant construction material.