No Detail Found!

Bacteria colonizing central venous catheter line and their Antimicrobial susceptibility pattern

Author(s)
Saeeda Nabat-ul-Hassan Department of Pathology, Sahara Medical College Narowal, Bolan Medical College and Hospital Quetta, RHC Akhtar Abad and Avicenna Medical College Lahore, Pakistan
Khushbu Farva Department of Pathology, Sahara Medical College Narowal, Bolan Medical College and Hospital Quetta, RHC Akhtar Abad and Avicenna Medical College Lahore, Pakistan
Yasmeen Lashari Department of Pathology, Sahara Medical College Narowal, Bolan Medical College and Hospital Quetta, RHC Akhtar Abad and Avicenna Medical College Lahore, Pakistan
Sadia Zia Department of Pathology, Sahara Medical College Narowal, Bolan Medical College and Hospital Quetta, RHC Akhtar Abad and Avicenna Medical College Lahore, Pakistan
Usman Ali Department of Pathology, Sahara Medical College Narowal, Bolan Medical College and Hospital Quetta, RHC Akhtar Abad and Avicenna Medical College Lahore, Pakistan
Mahreen Mahmood Department of Pathology, Sahara Medical College Narowal, Bolan Medical College and Hospital Quetta, RHC Akhtar Abad and Avicenna Medical College Lahore, Pakistan
Abstract
Objective: To determine the frequency of bacteria colonizing central venous catheter line and their antimicrobial susceptibility pattern. Methodology: This cross sectional study was conducted in the department of pathology, Sahara Medical College, Narowal from January to June 20201. Sample size was calculated using WHO sample size calculator and we used non-probability consecutive sampling technique.Central venous catheter tip colonization was defined as bacterial colony count =15 CFU/ml by semi quantitative technique. Antibiotic susceptibility pattern of isolated bacteria was determined using Disc Diffusion Method as recommended by CLSI guidelines. Data were analyzed using SPSS version 17. Results: A total 125 specimens were obtained from 125 patients. Micro-organisms growth was obtained on 110(88%) specimens. Gram-positive bacteria were isolated in 60(54.5%) specimens, gram-negative bacteria in 23(20.9%) specimens. Vancomycin and linezolid were most effective against gram positive bacteria while colistin and imipenem against gram negative organisms. Conclusion: Bacteria colonizing central venous catheter line were very common. Most organisms were gram positive and sensitive to vancomycin and linezolid.
Publication Details
Page(s) 22-25
DOI DOI not available
Published Journal: Rawal Medical Journal, Volume: 47, Issue: 1, Year: 2022

Request the full text from PASTIC

Keywords
Antimicrobial susceptibility, isolated bacteria, central venous catheter
0

Citations

0

Downloads

134

Views