No Detail Found!

Epidemiological Investigation and Development of Loop Mediated Isothermal Amplification for the Diagnosis of Ovine Theileriosis

Author(s)
Muhammad Arfan Zaman Department of Pathobiology, University of Veterinary and Animal Sciences,Lahore (Jhang Campus), Pakistan
Azhar Rafique Department of Zoology, GC University Faisalabad, Pakistan
Uzma Mehreen Department of Pathobiology, University of Veterinary and Animal Sciences,Lahore (Jhang Campus), Pakistan
Saba Mehnaz Department of Parasitology, University of Agriculture, Faisalabad, Pakistan
Farhan Ahmad Atif Department of Clinical Medicine and Surgery, University of Veterinary and Animal Sciences, Lahore, Pakistan
Asghar Abbas Department of Veterinary and Animal Sciences, Muhammad Nawaz Sharif University of Agriculture Multan, Pakistan
Kashif Hussain Department of Veterinary and Animal Sciences, Muhammad Nawaz Sharif University of Agriculture Multan, Pakistan
Muhammad Asif Raza Department of Veterinary and Animal Sciences, Muhammad Nawaz Sharif University of Agriculture Multan, Pakistan
Sidra Altaf Department of Pharmacy, University of Agriculture,Faisalabad,Pakistan
Faisal Siddique Department of Microbiology, Cholistan University of Veterinary and Animal Sciences, Bahawalpur, Pakistan
Rahman Md. Masudur Department of Pathology, Faculty of Veterinary, Animal and Biomedical Sciences, Sylhet Agricultural University,Sylhet-3100,Bangladesh
Mosaab Omar Department of Veterinary Medicine, College of Agriculture and Veterinary Medicine, Qassim University, 51452 Qassim, Saudi Arabia; Department of Parasitology, Faculty of Veterinary Medicine, South-Valley University, Qena 83523, Egypt
Abstract
Small ruminant industry is threatened in tropical and sub-tropical countries due to a Theileria (T.) lestoquardi, a haemoprotozoan. A Loop-Mediated Isothermal Amplification (LAMP) assay was developed for diagnosis of T. lestoquardi, a major cause of ovine theileriosis. The primers were designed based on the clone-5 sequence of T. lestoquardi. Four types of geo-climatic regions were selected for sampling. Towards this end, 56% sheep were infected with T. lestoquardi in the study area. 9.1% were found infected by using Giemsa staining technique, whereas, 13 and 17.1% by polymerase chain reaction (PCR) and loop mediated isothermal amplification (LAMP), respectively. PCR was considered a reference test to evaluate specificity and sensitivity of LAMP. The relative specificity and sensitivity of LAMP assay was 94.4 and 78%, respectively. Findings of LAMP assay revealed that the highest prevalence was detected in Bahawalpur (21.6% 19/88*100) followed in order by Jhang (17.04% 15/88*100), Sahiwal (15.09% 14/88*100) and Faisalabad (13.63% 12/88*100). LAMP assay found most suitable test for diagnosis of T. lestoquardi. This is anticipated that this study will provide a base-line data for caretakers and veterinary personnel to devise an improved scheme for the effective control of ovine theileriosis.
Publication Details
Page(s) 370-375
Published Journal: Pakistan Veterinary Journal, Volume: 42, Issue: 3, Year: 2022

Request the full text from PASTIC

Keywords
PCR, diagnosis, LAMP., Specificity and sensitivity, Giemsa staining, Ovine theileriosis
0

Citations

0

Downloads

41

Views