No Detail Found!

Comparison of shear bond strength of fifth and seventh generation adhesive systems for ceramic orthodontic brackets

Author(s)
FAHAD CHAUDHRY Lahore Medical and Dental College, Lahore, Cell: 0092-333-4649544; House SD 98, Falcon complex Gulberg 3, Lahore.
ASMA SHAFIQ Room 120, Dental Section Lahore Medical and Dental College, Lahore
MAHAM ANJUM Lahore Medical and Dental College, Lahore Cell: 0092-332-4398361
MAIRA MUBASHAR Lahore Medical and Dental College, Lahore Cell: 0092-300-8018255
ASAD-UR-REHMAN Lahore Medical and Dental College Lahore, Cell: 0092-332-5229858
YUMNA PERVAIZ Lahore Medical and Dental College, Lahore Cell: 0092-321-8800742; House 22 B2 Zafar Road Lahore Cantt, Lahore
Abstract
Debonding forces can cause a fracture of ceramic brackets or adhesive system at tooth / resin interface, because, ceramic brackets have no bending ability. This in turn can create cracks in susceptible enamel. Therefore, safe debonding is considered to be one of the biggest concerns while using ceramic brackets. Aim of this study was to compare mean shear bond strength of ceramic brackets bonded with fifth generation {Transbond XT (3M UNITEK) bonding agent} versus seventh generation bonding agents {ADPER Prompt-L-pop (3M ESPE)}. This randomized control trial was done at the department of orthodontics, Lahore Medical and Dental College, Lahore, For six months i.e: 30th August 2019 to 29th February 2020. Sixty untreated maxillary & mandibular extracted premolars of age 12-35 years and both genders were collected from the Department of Orthodontics, Lahore Medical and Dental College (LMDC), Lahore. Defective, restorative and anomalous premolars were excluded. In group A, 5th generation bonding material (Conventional system) was applied. In group B, 7th generation bonding material (Self Etch Primer) was applied. Universal testing machine (Instron) was used to measure shear bond strength. The mean shear bond strength of brackets was 16.40 ± 3.47 MPa in fifth generation group while 11.40 ± 1.40 MPa in seventh generation group (p-value = 0.0001). This study concluded that mean shear bond strength of brackets bonded with fifth generation bonding agent is greater than brackets bonded with seventh generation adhesive.
Publication Details
Page(s) 125-128
DOI DOI not available
Published Journal: Pakistan Oral and Dental Journal, Volume: 42, Issue: 3, Year: 2022

Request the full text from PASTIC

Keywords
Shear Bond Strength, Adhesive systems, Comparison.
0

Citations

0

Downloads

26

Views