No Detail Found!

Determination of optimum blending ratios of Sor-range with Indonesian coal for maximum utilization of Indigenous coal in Cement Industries

Author(s)
Tufail Ahmed Department of Mining Engineering, Balochistan University of Information Technology, Engineering and Management Sciences. Quetta, Pakistan
Zaheer Ahmed Kasi Department of Mining Engineering, Balochistan University of Information Technology, Engineering and Management Sciences. Quetta, Pakistan
Sami Ullah. Department of Mining Engineering, Balochistan University of Information Technology, Engineering and Management Sciences. Quetta, Pakistan
Abbas Hussain Department of Mining Engineering, Balochistan University of Information Technology, Engineering and Management Sciences. Quetta, Pakistan
Zahid Hussain Department of Mining Engineering, Balochistan University of Information Technology, Engineering and Management Sciences. Quetta, Pakistan
Asif Abbas Department of Geological Engineering, Balochistan University of Information Technology, Engineering and Management Sciences. Quetta, Pakistan
Fahim Ahmed Ibupoto Department of Mining Engineering, Balochistan University of Information Technology, Engineering and Management Sciences. Quetta, Pakistan
Abstract
The indigenous coal is not being used in cement industries due to low-quality constraints. In Pakistan, coal blending is not being generally practiced yet. In this research we utilize the Sor Range coal as a partial substitute of Indonesian coal by carrying out coal blending to meet the quality requirements of cement industries. To optimize the coal blending ratio, Indonesian coal was mixed with Sor-Range coal, and blends were made. Using proximate analysis, coal parameters such as moisture, volatile matter, ash and fixed carbon were determined. Calorific value and sulphur content were determined by using Oxygen Bomb Calorimeter and CarbonHydrogen-Sulphur Determinator (CHS-580) respectively. Experimental results of ash, moisture, fixed carbon, volatile matter and heating value of Sor-Range coal meet the required coal quality except for the Sulphur value. Based on laboratory testing results, it was found that the Sor-Range coal is unsuitable to be used for the cement industries, due to the presence of high Sulphur content. It is found that all blended ratios meet the required specification of cement industries except blend-1 and blend-2. The optimum blend percent ratio is 80:20 i.e. 80% Indonesian coal (imported coal) and 20% Sor-Range coal (local coal). The research outcome is financial saving by minimizing the import of foreign coal.
Publication Details
Page(s) 16-20
Published Journal: Journal of Applied and Emerging Sciences , Volume: 12, Issue: 1, Year: 2022

Request the full text from PASTIC

Keywords
proximate analysis, calorific value, Coal blending, Blending Ratios
0

Citations

0

Downloads

47

Views