No Detail Found!

The ideal profile (increase in B-lines/delta B-lines) on lung ultrasound for diagnosing weaning induced pulmonary edema in ventilated patients

Author(s)
Ghulam Rasheed Tabba Heart Institute, Karachi, Pakistan
Zahid Siddique Shad Indus Hospital, Muzaffargarh, Pakistan
Tooba Mehreen Shifa International Hospital, Islamabad, Pakistan
Nusrat Kharadi Shifa International Hospital, Islamabad, Pakistan
Moazma Ramzan Shifa International Hospital, Islamabad, Pakistan
Azmat Abdullah Shifa International Hospital, Islamabad, Pakistan
Kiran Abbas Jinnah Post Graduate Medical Center, Karachi, Pakistan
Abstract
Objective: To ascertain the ideal number of B-lines on lung ultrasound for the diagnosis of weaning induced pulmonary edema in ventilated patients. Study Design: Prospective observational study. Place and Duration of Study: Department of Medicine, Shifa International Hospital, Islamabad, from Jan to Aug 2020. Methodology: All the patients over the age of 18 years who were on mechanical ventilation in a medical intensive care unit were included in the study. The patients were given spontaneous breathing trials as a protocol for weaning from mechanical ventilation. Lung ultrasound was performed on 4 points of anterior chest wall before and after spontaneous breathing trials. Before and after spontaneous breathing trials counting of B lines was done on ultrasound of lung and comparison of increase in B lines (Delta-B-lines) was done with reference diagnosis of weaning induced pulmonary edema diagnosed by intensivist who was blinded to the results of lung ultrasound. Results: The study included 42 patients including 23 (54.8%) men and 19 (45.2%) women. 14 cases failed spontaneous breathing trials. Seven cases (16.7%) had weaning induced pulmonary edema. Delta-B-lines =6 diagnosed weaning induced pulmonary edema with 100% accuracy. Out of the remaining seven patients with weaning failure but without weaning induced pulmonary edema, 6 (28.6%) had Delta-B-lines =6. The ultrasound lung technique had a 100% sensitivity profile to detect weaning induced pulmonary edema and a specificity of 77.78%. Conclusion: The study indicates that Delta-B-lines =6 diagnosed the weaning induced pulmonary edema with the best accuracy.
Publication Details
Page(s) 2220-2223
Published Journal: Pakistan Armed Forces Medical Journal, Volume: 71, Issue: 6, Year: 2021

Request the full text from PASTIC

Keywords
Mechanical ventilation, Spontaneous breathing trials, Ideal profile, Weaning induced pulmonary edema, Heart failure.
0

Citations

0

Downloads

63

Views