No Detail Found!

Comparison of endotracheal intubation versus supraglottic airway device in patients undergoing corneal transplantation under general anaesthesia

Author(s)
Sana Abbas Armed Forces Institute of Ophthalmology/National University of Medical Sciences (NUMS) Rawalpindi, Pakistan
Omar Zafar Armed Forces Institute of Ophthalmology/National University of Medical Sciences (NUMS) Rawalpindi, Pakistan
Beenish Abbas Armed Forces Institute of Ophthalmology/National University of Medical Sciences (NUMS) Rawalpindi, Pakistan
Basit Mehmood Armed Forces Institute of Ophthalmology/National University of Medical Sciences (NUMS) Rawalpindi, Pakistan
Umer Hayat Armed Forces Institute of Ophthalmology/National University of Medical Sciences (NUMS) Rawalpindi, Pakistan
Hassaan Javaid Armed Forces Institute of Ophthalmology/National University of Medical Sciences (NUMS) Rawalpindi, Pakistan
Abstract
Objective: To compare endotracheal intubation versus Suraglottic airway device in patients undergoing penetrating keratoplasty under general anaesthesia. Study Design: Quasi-experimental study. Place and Duration of Study: Armed Forces Institute of Ophthalmology, Rawalpindi, from Jan 2018 to Mar 2020. Methodology: Total 28 patients enrolled with a mean age of 42.82 ± 7.86 years and age-range of 18-55 belonging to American Society of Anesthesiology I, II & III undergoing penetrating keratoplasty under general anaesthesia. The airway was secured with I-Gel and Endotracheal tube in group A (n=14) and group B (n=14) respectively. Pre anaesthesia assessment along with informed written consent performed. General Anesthesia is given and patients monitored as per standard protocols. Postextubation incidence of cough, sore throat, bronchospasm, stridor and blood on device recorded in addition to surgery and recovery duration. Results: Twenty-eight patients were enrolled in the study with a mean age of 42.82 ± 7.86 years. There were 9 (32.1%) females and 19 (67.9%) males in the study group. The recovery time was significantly lower for group A as compared to group B (72.64 ± 5.06 vs 80.43 ± 3.75, p<0.001). Similarly, a significantly lesser number of patients experienced post-extubation complications i.e. cough, among group A as compared to Group B [1 (7.1%) vs 8 (57.1%) p0.005]. Conclusion: I-Gel provides smooth recovery with reduced mean recovery time and decreased potential of raised intraocular pressure, when compared with endotracheal intubation in patients undergoing penetrating keratoplasty under general anaesthesia.
Publication Details
Page(s) 1420-1424
DOI DOI not available
Published Journal: Pakistan Armed Forces Medical Journal, Volume: 71, Issue: 4, Year: 2021

Request the full text from PASTIC

Keywords
Penetrating keratoplasty, Supraglottic airway device, Endotracheal intubation.
0

Citations

0

Downloads

97

Views