No Detail Found!

Carbon Monoxide Concentrations in Kitchens of Gas-fired Burners, Karachi, Pakistan

Author(s)
Zafar Iqbal Shams Institute of Environmental Studies, University of Karachi,Karachi,Pakistan
Tariq Javed Government Degree College for Men,Nazimabad, Karachi,Pakistan
Arif Zubair Department of Environmental Science, Federal Urdu University of Arts, Science & Technology,Karachi,Pakistan
Muhammad Waqas Institute of Environmental Studies, University of Karachi,Karachi,Pakistan
Saira Ali Institute of Environmental Studies, University of Karachi,Karachi,Pakistan
Anusha Ahmed Institute of Environmental Studies, University of Karachi,Karachi,Pakistan
Abstract
In this study, gas-fired kitchens of 54 bungalows and 25 apartments were studied using stationary indoor carbon monoxide (CO) monitoring. The levels of CO were measured in each kitchen for a period of 24 h with a 1 min resolution using data logger EL-USB-CO300. Hourly, 8 h and 24 h, CO means for all the kitchens were calculated. Hourly and 24 h CO means of kitchens for bungalows were 3.72±6.26 ppm and 3.72±3.16 ppm, respectively, while those apartments have 3.74±6.96 ppm and 3.74±2.17 ppm, respectively. 8 h CO means of night, day and evening in the kitchens of bungalows were 2.62±3.22 ppm, 4.85±4.66 ppm and 3.53±3.30 ppm, respectively, while in apartments 2.13±2.02 ppm, 3.79±3.86 ppm and 5.29±4.17 ppm. The mean difference between the 8 h CO concentrations during the evening in bungalows and apartments was 1.76±0.87 ppm (P<0.01). 20% of kitchens apartment and 16.67% of bungalows which exceeded the WHO guidelines for daily exposure limit.
Publication Details
Page(s) 25-32
DOI DOI not available
Published Journal: Pakistan Journal of Scientific and Industrial Research (Series A: Physical Sciences), Volume: 65, Issue: 1, Year: 2022

Request the full text from PASTIC

Keywords
Karachi, Natural gas, Cooking, indoor pollutant, carbon monoxide
0

Citations

0

Downloads

63

Views