No Detail Found!

Diagnostic Accuracy of Peroperative Color Doppler Ultrasonography for Determining the Nature of Anterolateral Thigh Flap Perforators

Author(s)
Mohsin Ata Pak Italian Modern Burn and Plastic Surgery Centre, Nishtar Hospital, Multan, Pakistan
Muhammad Naveed Shahzad Pak Italian Modern Burn and Plastic Surgery Centre, Nishtar Hospital, Multan, Pakistan
Ahmad Ali Pak Italian Modern Burn and Plastic Surgery Centre, Nishtar Hospital, Multan, Pakistan
Abstract
Objective: To determine the diagnostic accuracy of color Doppler ultrasonography for diagnosing the septocutaneous nature of anterolateral thigh flap perforators, taking peroperative findings as the gold standard among patients undergoing soft tissue reconstruction. Methodology: A total of 100 patients undergoing soft tissue reconstruction using antero-lateral thigh flap perforators at the plastic surgery unit, Pak Italian Modern Burn Center, Multan from January 2018 to December 2020. Information regarding their demographic data was noted in the proforma. A high frequency color Doppler ultrasound was done by the consultant radiologist to determine the nature of the perforator as per operational definition. The anterolateral thigh thin flap was undermined, but kept in situ. The elevation was performed either on the superficial or sub-facial plane depending upon the situation and surgical plan, and the points of emergence through the deep fascia and nature of its perforators, as they appeared during surgery. All Data was entered and analyzed using SPSS version 24.0. Results: Age distribution of the patients was done, it showed that out of 100 patients, 17 %( n=17) were in age group of 15-27 years and 83%( n=83) were in age group of 28-40 years and mean age was calculated as 33.96±5.72 years. Gender distribution of the patients was done. It showed that 88 %( n=88) were male whereas 12% (n=12) were females. In this study, the sensitivity and specificity of the septocutaneous nature of perforator was 78.41% and 83.33% respectively, and PPV was 97.18% and NPV was 34.48% and accuracy was 79%. Conclusion: Color doppler ultrasonography is a reliable test for predicting the nature of the anterolateral thigh flap perforator.
Publication Details
Page(s) 67-71
DOI DOI not available
Published Journal: Annals of the Pakistan Institute of Medical Sciences, Volume: 18, Issue: 1, Year: 2022

Request the full text from PASTIC

Keywords
Color doppler ultrasonography, Anterolateral thigh flap, per-operative finding.
0

Citations

0

Downloads

62

Views