The rationale of this study was to assess the hospital waste management system at different medical wards and to determine the total daily waste generation rates at Shaheed Mohatrama Benazir Bhutto Medical University (SMBBMU) Hospital Larkana. For that purpose a detailed survey of hospital was conducted through a questionnaire, and personal interviews from selected staff and public. The acquired data was documented for waste generation, segregation, collection procedures, type of containers and storage, onsite and off-site transport, treatment of hospital waste and final disposal options. The number of beds, bed occupancy rate and number of operations performed during the year 2011 were also recorded. It was found that the average generation rate of hospital and infectious waste was about 1.072 and 0.453 kg/bed/day respectively. The maximum amount of infectious waste was recorded in Surgical-III ward with 49% and minimum amount was reported in ENT with 26% of the total hospital waste. It was discovered from the study that the existing hospital waste management system was lower than standards. The poor waste management system in the hospital was mainly due to ineffective segregation, collection, storage and dumping of waste. In addition, lack of training and protective equipment for sanitary staff, scarcity of funds and indefinite policy of waste treatment were also the main causes of inappropriate waste management. It was concluded from the study that clear lines of responsibilities and proper management system could be supportive for up-gradation of public health as well as hygienic conditions in the hospital.