No Detail Found!

Does the Cementless, Hydroxyapatite on Porous, Long-stem Prosthesis Perform Well in Revision Total Hip Arthroplasty? A Multicenter Observation

Author(s)
Jinwen He Department of Orthopaedics, Lanzhou University Second Hospital, Orthopaedics Key Laboratory of Gansu Province, Orthopaedics Clinical Research Centre of Gansu Province,Lanzhou, Gansu,China
Xingwen Wang Department of Orthopaedics, Lanzhou University Second Hospital, Orthopaedics Key Laboratory of Gansu Province, Orthopaedics Clinical Research Centre of Gansu Province,Lanzhou, Gansu,China
Bin Geng Department of Orthopaedics, Lanzhou University Second Hospital, Orthopaedics Key Laboratory of Gansu Province, Orthopaedics Clinical Research Centre of Gansu Province,Lanzhou, Gansu,China
Xinxin Yang Department of Orthopaedics, Gansu Province People's Hospital,Lanzhou, Gansu,China
Zhu Liang Department of Orthopaedics, New City District of Jiuquan People's Hospital,Jiuquan, Gansu,China
Yayi Xia Department of Orthopaedics, Lanzhou University Second Hospital, Orthopaedics Key Laboratory of Gansu Province, Orthopaedics Clinical Research Centre of Gansu Province,Lanzhou, Gansu,China
Abstract
Objective: To determine the multicenter outcomes of the cementless, hydroxyapatite on the porous, long-stem prosthesis for revision total hip arthroplasty (THA) at multiple centres. Study Design: Observational study. Place and Duration of Study: Lanzhou University Second Hospital, Gansu Province People's Hospital, New City District of Jiuquan People's Hospital, from March 2014 to December 2019. Methodology: The database in three centres was retrospectively reviewed hip arthroplasty during the study period. Patients who underwent revision THA using the cementless, hydroxyapatite on porous, long-stem femoral prostheses were included. Perioperative complications, functional outcomes including the Merle d Aubign e-Postel hip questionnaire (MAP), Harris Hip Score (HHS), Oxford Hip Score (OHS), Western Ontario and McMaster Universities (WOMAC) Osteoarthritis Index, life independence, and patient satisfaction were analyzed, the radiographic evaluation was also performed. Results: Fifty revision THA (50 hips) were included for analysis, the median interval between primary and index revision procedure was 5.1 (0.3-30) years, and the rate of perioperative complications was 18%. Patients were followed up for a mean of 3.1±1.5 (1.1-6.5) years. At the latest follow-up, the functional outcomes signi cantly increased compared to preoperative data (p<0.001). Thirty-nine patients (92.9%) were life-independent, and 36 patients (85.7%) were satis ed with the surgery. Subsidence was observed in 5 patients, osteolysis occurred in 3 patients, and no revision was required. Conclusion: The cementless, hydroxyapatite on porous, long-stem prosthesis was a good choice for revision THA with a poor bone condition in the proximal femur, unstable PFF, and recurrent dislocations after THA, no severe complications were found.
Publication Details
Page(s) 885-889
DOI DOI not available
Published Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 32, Issue: 7, Year: 2022

Request the full text from PASTIC

Keywords
Arthroplasty, Hip prosthesis, Reoperation