No Detail Found!

ChromagarTM Col-Apse for Detection of Colistin Resistance in Clinical Isolates of Multidrug Resistant Gram Negative Bacilli

Author(s)
Saad Ali Department of Microbiology, Armed Forces Institute of Pathology (AFIP),Rawalpindi,Pakistan
Wajid Hussain Department of Microbiology, Armed Forces Institute of Pathology (AFIP),Rawalpindi,Pakistan
Farooq Ahmed Department of Microbiology, Armed Forces Institute of Pathology (AFIP),Rawalpindi,Pakistan
Raja Kamran Afzal Department of Microbiology, Armed Forces Institute of Pathology (AFIP),Rawalpindi,Pakistan
Irfan Mirza Department of Microbiology, Armed Forces Institute of Pathology (AFIP),Rawalpindi,Pakistan
Umer Khurshid Department of Microbiology, Armed Forces Institute of Pathology (AFIP),Rawalpindi,Pakistan
Abstract
Objective: To determine the diagnostic accuracy of CHROMagaTrM COL-APSE, for detection of colistin resistance in clinical isolates of multi drug resistant (MDR) gram negative bacilli (GNB). Study Design: Cross-sectional validation study. Place and Duration of Study: Department of Microbiology, Armed Forces Institute of Pathology (AFIP), Rawalpindi, Pakistan from February 2019 to August 2019. Methodology: Total 96 MDR-GNB in clinical isolates were included. Isolates were identi ed using gram stain, catalase, oxidase, API 20E and API 20NE. After taking approval from Institutional Ethical Review Committee, colistin susceptibility was determined simultaneously by CHROMagarTM COL-APSE (using 1x105 CFU/ml inoculum) and Broth Micro Dilution (BMD) Minimum Inhibitory Concentration (MIC) method as per CLSI. EUCAST guidelines were followed for interpretation of susceptibility pro le. Results were validated with gold standard test, i.e. BMD. Results: Out of 96 MDR clinical isolates, the distribution was K. pneumoniae n=63, E. coli n=18, A. baumannii n=11, C. freundii n=3, and E. cloacae n=1. The sensitivity, speci city, positive predictive value, negative predictive value and diagnostic accuracy of CHROMagarTM COL-APSE for detection of colistin resistance, keeping BMD-MIC method as gold standard, was 97.96%, 97.87%, 97.96%, 97.87% and 97.92%, respectively. Conclusion: CHROMagarTM COL-APSE can be used as screening agar by direct streaking of specimen as well as diagnostic for detection of colistin resistance by the use of standardised inoculum. It can be used as a critical time saving method for colistin resistance detection in absence of expertise or manpower required for BMD as well as the cost required for genetic sequencing to detect MCR genes.
Publication Details
Page(s) 177-180
DOI DOI not available
Published Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 32, Issue: 2, Year: 2022

Request the full text from PASTIC

Keywords
Colistin resistance, Gram negative bacilli (GNB), CHROMagarTM COL-APSE, Multi drug resistant (MDR)