Finite element modelling and analysis of three bays three stories, two-dimensional reinforced concrete (RC) frame were performed to evaluate the seismic performance of structures with infill masonry assuming the structure to be constructed in the seismic zone 3, according to the building code of Pakistan. Two types of Masonry RC frames were modelled, first with full infill walls (FIF) and secondly with a soft story (SSF) at ground floor. Subsequently, the analytical results were compared with that of the performance of the bare frame (BF) model, considered as reference. FEMA and ATC 40 guidelines were used to include the effect of masonry walls. The overall performance of all three models were evaluated in terms of the fundamental modal time period, maximum inter-story drift ratio (MIDR), relative displacement (RD), stiffness, and performance points as per ATC 40 capacity spectrum method. The study confirmed that the structural performance of full masonry infill walls frame model (FIF) was better than the other two. The study also revealed that the single strut model was unable to capture the real behaviour of the infill wall in RC structures, favouring the use of multi diagonal struts macro modelling techniques.