No Detail Found!

Comparison of visibility and block success between Echoplex+® and Stimuplex®-Ultraline 360○ echogenic needles for ultrasound-guided supraclavicular brachial plexus block for upper limb surgery

Author(s)
Suki Ismet Department of Anesthesiology, School of Medical Sciences, Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia.
Wan Mohd Nazaruddin Wan Hassan Department of Anesthesiology, School of Medical Sciences, Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia.
Mohd Zulfakar Mazlan Department of Anesthesiology, School of Medical Sciences, Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia.
Laila Ab Mukmin Department of Anesthesiology, School of Medical Sciences, Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia.
Soon Eu Chong Department of Anesthesiology, School of Medical Sciences, Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia
Rhendra Hardy Mohamad Zaini Department of Anesthesiology, School of Medical Sciences, Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia.
Abstract
Background: Needle visibility is an important factor in the success of ultrasound-guided peripheral nerve block. This study aimed to compare needle visibility, block performance, time to perform block and the block success by the two echogenic needles, the Echoplex+® and the Stimuplex® Ultraline 360°, during ultrasound-guided supraclavicular brachial plexus block (SBPB). Methodology: Seventy patients scheduled for upper limb surgery under SBPB were randomised into two groups: Group E (n = 35) was blocked using an Echoplex+® needle and Group S (n = 35) was blocked using a Stimuplex® Ultraline 360° needle. All patients received 20 ml of ropivacaine 0.75% using the same brand of ultrasound machine. The needle visibility, time to perform block and block success were recorded. Results: Needle visibility was not found to be significantly different between the groups (p = 0.241). The medians of the time to perform block (11.0 [IQR 6] vs. 10.0 [IQR 4] min; p = 0.278) and the percentages of adequate blocks (p = 0.565) were also not found to be statistically significantly different. Conclusion: No statistically significant differences, in terms of needle visibility, time to perform block and the block success, were found between the Echoplex+® and the Stimuplex® Ultraline 360° block needles during supraclavicular brachial plexus block. Hence, both were equally effective for the performance of the block.
Publication Details
Page(s) 788-792
Published Journal: Anaesthesia, Pain and Intensive Care, Volume: 25, Issue: 6, Year: 2021

Request the full text from PASTIC

Keywords
Visibility, Ultrasound-guided, Echogenic needle, Brachial plexus, Supraclavicular block