No Detail Found!

METHOD DEVELOPMENT, VALIDATION AND CALCULATION OF UNCERTAINTY FOR THE DETERMINATION OF LAMBDA- CYHALOTHRIN FROM COMMERCIAL FORMULATIONS THROUGH REVERSE-PHASE LIQUID CHROMATOGRAPHIC APPROACH

Author(s)
Zeshan Aslam Pesticide Quality Control Laboratory, Institute of Soil Chemistry and Environmental Sciences, Kala Shah Kaku, Pakistan
Muhammad Aslam Avais Pesticide Quality Control Laboratory, Institute of Soil Chemistry and Environmental Sciences, Kala Shah Kaku, Pakistan
Muhammad Rashid Farooq Pesticide Quality Control Laboratory, Institute of Soil Chemistry and Environmental Sciences, Kala Shah Kaku, Pakistan
Muhammad Adnan Rafique Pesticide Quality Control Laboratory, Institute of Soil Chemistry and Environmental Sciences, Kala Shah Kaku, Pakistan
Muhammad Zia Ul Haq Department of Agronomy, University of Agriculture, Faisalabad, Pakistan
Arslan Nazarat Pesticide Quality Control Laboratory, Institute of Soil Chemistry and Environmental Sciences, Kala Shah Kaku, Pakistan
Ali Afzal Pesticide Quality Control Laboratory, Institute of Soil Chemistry and Environmental Sciences, Kala Shah Kaku, Pakistan
Muhammad Awais Khalid Pesticide Quality Control Laboratory, Institute of Soil Chemistry and Environmental Sciences, Ayub Agricultural Research Institute, Faisalabad, Pakistan
Abstract
Lambda-cyhalothrin is a pyrethroid insecticide posing an implicit curb on the pest of different crops especially cotton. The focus of the present study was the development and validation of a test procedure for the quantitative measurement of lambda-cyhalothrin from its different formulations and calculation of uncertainty. The objective of this validation method was to demonstrate its reliability for the desired application. This study was conducted at Pesticide Quality Control Laboratory, Kala Shah Kaku, Pakistan during 2019. Lambda-cyhalothrin was quantified by liquid chromatography with a diode array detector (DAD). The estimation was evaluated on agilent high performance liquid chromatograph (HPLC) equipped with C18 column using acetonitrile and water (85:15) as mobile phase. different steps of method validation, i.e., accuracy, precision, linearity, recovery percentage, the limit of detection (LOQ) and quantification (LOD) were performed and uncertainty was calculated according to the instruction on the validation of an analytical test method. The obtained data showed that the test method was accurate (99.25% accuracy), reliable (%RSD of repeatability 0.379), precise (%RSD of reproducibility 0.30), and high recovery percentage, i.e., 102.7%. The LOQ and LOD of this test method was 0.002% and 0.01%, respectively. The uncertainty value of this test method for the determination of lambda-cyhalothrin (2.70%) from its formulation was observed that was, 0.016%w/w with a 5% probability level. The findings of the study validated that the method were substantiated and all the observations fall within the appropriate limit. The developed method was considerably adoptive due to its simplicity, reliability, and practicality. Hence, the proposed method had the potential to be adopted for routine analysis with ease and convenience.
Publication Details
Page(s) 271-278
DOI DOI not available
Published Journal: Journal of Agricultural Research, Volume: 59, Issue: 3, Year: 2021

Request the full text from PASTIC

Keywords
Pakistan, Validation, Robustness, liquid chromatography, Pyrethroids, uncertainty