No Detail Found!

Relationship between 3D Power Doppler Ultrasound and Serum MMP-2 and Ang-2 Levels in Pregnant Women with Preeclampsia

Author(s)
Xiaoyu Lin Department of Ultrasound, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University,China
Xiuping Zhou Department of Ultrasound, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University,China
Huipei Jin Department of Ultrasound, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University,China
Yaping Zhao Department of Ultrasound, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University,China
Abstract
Objective: To explore the relationship between 3D power Doppler ultrasound (3D-PDU) and serum MMP-2 and Ang-2 levels in pregnant women with preeclampsia (PE). Study Design: Comparative analytical study. Place and Duration of Study:The Second A liated Hospital and Yuying Children's Hospital of Wenzhou Medical University, China, from October 2017 to January 2020. Methodology: One hundred and thirty-four pregnant women with PE were selected as the research subjects, with 67 cases in mild group and 67 cases in severe group. Sixty-seven healthy primigravidas were selected as normal control group. Serum MMP-2 and Ang-2 were detected. All subjects underwent prenatal 3D-PDU examination, and VI, FI and VFI were measured. Results: Compared to normal control group, serum MMP-2 and Ang-2 levels of mild group and severe group decreased successively (all p <0.001); VI, FI, and VFI of mild group and severe group decreased successively (both p <0.001). Pearson correlation analysis showed that serum MMP-2 in pregnant women with PE was positively correlated with VI, FI, VFI (r = 0.940, p <0.001, r = 0.938, p <0.001, and r = 0.921, p <0.001, respectively); and serum Ang-2 was positively correlated with VI, FI, VFI (r = 0.958, p <0.001; r = 0.960; p <0.001; r = 0.945, p <0.001, respectively). Conclusion: 3D-PDU has a certain application value in the diagnosis of pregnant women with PE, variation tendency of VI, FI and VFI detected by 3D-PDU is closely associated with serum MMP-2 and Ang-2 levels.
Publication Details
Page(s) 810-814
DOI DOI not available
Published Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 30, Issue: 8, Year: 2020

Request the full text from PASTIC

Keywords
Pregnant women, Preeclampsia, Ang-2, MMP-2, 3D power Doppler ultrasound (3D-PDU)
0

Citations

0

Downloads

43

Views