No Detail Found!

Erythrocyte Autoantibody Positivity in Serological Cross-matching

Author(s)
Bulent Atik Faculty of Medicine, Department of Anesthesiology and Reanimation, Balıkesir University, Turkey
Tugba Kula Atik Faculty of Medicine, Department of Anesthesiology and Reanimation, Balıkesir University, Turkey
Hulya Duran Faculty of Medicine, Department of Anesthesiology and Reanimation, Balıkesir University, Turkey
Ozgur Baykan Faculty of Medicine, Department of Anesthesiology and Reanimation, Balıkesir University, Turkey
Tuba Ersal Faculty of Medicine, Department of Anesthesiology and Reanimation, Balıkesir University, Turkey
Emine Avci Faculty of Medicine, Department of Anesthesiology and Reanimation, Balıkesir University, Turkey
Emre Ispir Faculty of Medicine, Department of Anesthesiology and Reanimation, Balıkesir University, Turkey
Bayhan Bektore Faculty of Medicine, Department of Anesthesiology and Reanimation, Balıkesir University, Turkey
Abstract
Objective: To investigate the erythrocyte autoantibody positivity detected in the serological cross-matching (XM), and its possible e ects on salient hemogram parameters. Study Design: A descriptive study. Place and Duration of Study: Bal1kesir Atatürk City Hospital s Blood Transfusion Centre, Faculty of Medicine, Department of Anesthesiology and Reanimation, Bal1kesir University, Turkey, from 2017 to 2018. Methodology: Erythrocyte autoantibody positivity, which was detected in the traditional serological cross-matching for a pre-transfusion laboratory test were analysed retrospectively. Later, hemogram changes in the previous (no erythrocyte autoantibodies) and following (erythrocyte autoantibodies present) transfusions were investigated using statistical methods. Results: Erythrocyte autoantibody positivity rate was 10.16% (342/3,365). There was no statistically signi cant di erence in the increase of hemoglobin, hematocrit, and red blood cell between the period when erythrocyte autoantibodies were detected or not, (p = 0.27, 0.13, and 0.09, respectively). Conclusion: Erythrocyte autoantibodies positivity found on routine cross-match exmination, which must be considered together with parameters such as previous transfusion history, other pre-transfusion laboratory test results, and clinical presentation and management.
Publication Details
Page(s) 485-489
DOI DOI not available
Published Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 30, Issue: 5, Year: 2020

Request the full text from PASTIC

Keywords
Transfusion, Erythrocye autoantibody, Cross-matching, Hemogram, Alloantibody
0

Citations

0

Downloads

60

Views