No Detail Found!

Optimisation of user-selectable volumetric modulated arc therapy (VMAT) planning parameters: VMAT arcs for prostate and head-and-neck cancers

Author(s)
Ghulam Murtaza Department of Medical Imaging, School of Health Sciences, University of Management and Technology,Lahore,Pakistan
Zaheer Abbas Gillani Department of Physics, BaluchistanUniversity of Information Technology, Engineering and Management Sciences,Quetta, Pakistan
Shahid Mehmood Department of Oncology,Combined Military Hospital, Rawalpindi, Pakistan
Jalil Ur Rehman Department of Physics, Khwaja Fareed University of Engineering and Information Technology, Rahim Yar Khan, Pakistan
Ehsan Ullah Khan Department of Mathematics, NAMAL INSTITUTE Mianwali,Pakistan
Abstract
Objective: To evaluate different VMAT planning techniques for a multi-leaf collimator (MLC)providing maximum aperture of 21 × 16 cm². Methods: A VMAT planning study of nine prostate and nine head-and-neck cancer patients was carried out. The patients were previously treated with Intensity Modulated Radiotherapy (IMRT) technique during 2014-15, at radiation oncology SanBortolo Hospital, Vicenza, Italy. Three VMAT plans for each of prostate and head-and-neck cancer patient were optimized using Pinnacle treatment planning system for 6MV photon beam from ElektaSynergyS®Linac system. Single arc, dual arc and combined two independent-single-arcs were optimized for collimator angle 45°. VMAT treatment planning comparison was made among single-arc dual-arc and combined two independent-single-arcs. The student's t-test (two-sided) with p = 0.05 was applied for significant difference between dose volume indices of plans. Results: All VMAT techniques produced clinically acceptable plans for prostate, while for head-and-neck, DA and ISAs significantly improved target coverage compared to SA. Single arc is sufficient for prostate, while inefficient in case of head-and-neck dose-planning. In spite of having different VMAT optimization approach dual arc and two combined independent-single-arcs provided very similar target coverage, while dual arc improved sparing of organs-at-risk. Similar treatment delivery times were observed for DA and ISAs VMAT techniques. Conclusion: Single arc is sufficient for prostate, while inefficient in case of head-and-neck dose-planning. Dual arc and two combined independent-single-arcs provided similar PTV coverage, while DA provided better sparing of organs at risk.
Publication Details
Page(s) 1093-1099
DOI DOI not available
Published Journal: Journal of Pakistan Medical Association, Volume: 71, Issue: 4, Year: 2021

Request the full text from PASTIC

Keywords
VMAT, Treatment planning, Limited aperture collimation system.
0

Citations

0

Downloads

61

Views