No Detail Found!

Comparative diagnostic accuracy of ultrasound and magnetic resonance imagingfor placenta accreta in previous scar patients taking clinical outcome as gold standard

Author(s)
Mubashrah Aziz Combine Militry Hospital, Quetta, Pakistan; National University of Medical Sciences (NUMS), Pakistan
Muhammad Omer Aamir Combine Militry Hospital, Quetta, Pakistan; National University of Medical Sciences (NUMS), Pakistan
Muhammad Atif Mian Combine Militry Hospital, Quetta, Pakistan; National University of Medical Sciences (NUMS), Pakistan
Yasar Shakeel Combine Military Hospital, Gujranwala, Pakistan; National University of Medical Sciences, Pakistan
Fareeha Awan Combine Military Hospital/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Samia Rauf Combine Military Hospital, Gujranwala, Pakistan; National University of Medical Sciences, Pakistan
Abstract
Objective: To compare the diagnostic accuracy of magnetic resonance imaging (MRI) and ultrasound (USG) in clinically suspected cases of placenta accreta in previous scar patients taking clinical outcome as Gold standard. Study Design: Cross-sectional validation study. Duration and Place of Study: Combined Military Hospital, Quetta Pakistan, from Oct 2016 to Mar 2017. Methodology: This study enrolled pregnant ladies having history of previous one or more caesarean sections, age ranging from 20-40 years and gestational age 37-41 weeks. The ultrasound & magnetic resonance imaging findings were recorded as positive or negative for placenta accreta and then correlated with clinical outcome. Results: The data of 155 patients were analysed. Out of 155, 86 patients were found to be positive on magnetic resonance imaging. Among them, 78 were found to be true positive and 8 were false positive. While among, 69 patients with negative findings on magnetic resonance imaging, 12 were false negative whereas 57 were true negative. Overall diagnostic accuracy, specificity, sensitivity, positive predictive value and negative predictive value of magnetic resonance imaging for placenta accreta was 87.09%, 82.60%, 90.69%, 86.67% & 82.69% respectively. In 82 patients with positive findings on ultrasound, 71 were true positive and 11 were found to be False Positive. While among, 73 ultrasound negative patients, 14 were false negative whereas 59 were true negative. Overall diagnostic accuracy, sensitivity, specificity, positive and negative predictive value of ultrasound for placenta accreta was 83.87%, 86.5%, 80.82%, 83.53% and 84.28% respectively. Conclusion: Magnetic resonance imaging andultrasonography are highly sensitive and accurate imaging modalities for diagnosing placenta accreta in previous scar patients and have comparable diagnostic accuracies.
Publication Details
Page(s) 1044-1048
DOI DOI not available
Published Journal: Pakistan Armed Forces Medical Journal, Volume: 71, Issue: 3, Year: 2021

Request the full text from PASTIC

Keywords
Ultrasound, placenta accreta, Magnetic Resonance Imaging, Sensitivity.
0

Citations

0

Downloads

82

Views