No Detail Found!

Evaluation of germicidal uv-c light for surface disinfection in a tertiary care hospital

Author(s)
Qanita Fahim Combined Military Hospital, Lahore, Pakistan; National University of Medical Sciences (NUMS), Pakistan
Nasir Uddin Combined Military Hospital, Lahore, Pakistan; National University of Medical Sciences (NUMS), Pakistan
Najam Ul Hassan Combined Military Hospital, Lahore, Pakistan; National University of Medical Sciences (NUMS), Pakistan
Nargis Sabir Combined Military Hospital Nowshera/National University of Medical Sciences (NUMS), Pakistan
Anam Tariq Combined Military Hospital, Lahore, Pakistan; National University of Medical Sciences (NUMS), Pakistan
Ayesha Bashir Combined Military Hospital, Lahore, Pakistan; National University of Medical Sciences (NUMS), Pakistan
Sarmad Ahmad NUST College of Electrical and Mechanical Engineering, Rawalpindi, Pakistan
Abstract
Objective: To check the efficacy of 36-Watt Ultraviolet-C tube light, in terms of distance and time against medically important microorganisms (Staphylococcus aureus, Escherichia coli, Pseudomonas aeroginosa, Candida albicans and Aspergillus species). Study Design: Quasi-experimental study. Place and Duration of Study: Pathology department, Combined Military Hospital, Lahore Pakistan, from Jun to Sep 2020. Methodology: ATCC control organisms of above mentioned bacteria, yeasts, and fungi were exposed to ultraviolet-C light for different times and distances to ascertain its germicidal effect. Two methods were selected, one in which micro-organisms inoculated plates were exposed to ultraviolet-C light and second in which McFarland suspensions of microorganisms were exposed before inoculation. Both the methods were compared. Observations were noted down after repeated performance of both the procedures. Results: An exposure time of 15 minutes, mean ± SD (13.8 ± 10.1) at 1-foot distance was proved ideal for all the tested bacteria, but yeasts and fungi required >30 minutes, mean ± SD (17.5 ± 13.5) to be killed. Moreover, distance and time of exposure were found out to be directly proportional irrespective of microbial load. Greater the distance longer the ultraviolet C exposure was required. Conclusion: Ultrviolet-C light 36-Watt can have efficient inactivation of bacterial, fungal and archaeal species up to 6 feet for >30 minutes exposure time. Ultraviolet-C light disinfection is best for areas like closed rooms, operation theatres, PCR Labs, and bio-safety cabinets keeping bio-safety guidelines in view.