This study was conducted in order to ascertain the present status of heavy metals in hand pumps and tap water of Mardan District. A total of eight heavy metals (Fe, Zn, Cu, Mn, Pb, Cr, Cd, and Ni) were investigated in hand pump and tap water samples collected in the study area. Atomic Absorption Spectrometry was used to determine the heavy metals. Fe, Zn, and Cu levels were within the permissible limits, while Pb, Cr, Cd and Ni levels in the study area exceeded the WHO permissible limits. The high concentration of heavy metals in the drinking water can be attributed to the corrosiveness and aggressiveness of the water in the study area.