Diagnostic Accuracy of Mammographic and Sonographic Findings in the Differentiation of Palpable Breast Masses taking Histopathology as a Gold Standard

Author(s)
Sadaf Ayesha University Institute of Radiological Sciences and Medical Imaging Technology, Faculty of Allied Health Sciences University of Lahore, Pakistan
Raham Bacha University Institute of Radiological Sciences and Medical Imaging Technology, Faculty of Allied Health Sciences University of Lahore, Pakistan
Mehreen Fatima University Institute of Radiological Sciences and Medical Imaging Technology, Faculty of Allied Health Sciences University of Lahore, Pakistan
Syed Amir Gilani University Institute of Radiological Sciences and Medical Imaging Technology, Faculty of Allied Health Sciences University of Lahore, Pakistan.
Tayyaba Akhter Radiology Department of Fatima Memorial Hospital
Syed Yousaf Farooq University Institute of Radiological Sciences and Medical Imaging Technology, Faculty of Allied Health Sciences University of Lahore, Pakistan
Muhammad Yousaf University Institute of Radiological Sciences and Medical Imaging Technology, Faculty of Allied Health Sciences University of Lahore, Pakistan.
Muhammad Uzair University Institute of Radiological Sciences and Medical Imaging Technology, Faculty of Allied Health Sciences University of Lahore, Pakistan
Mahjabeen Liaqat University Institute of Radiological Sciences and Medical Imaging Technology, Faculty of Allied Health Sciences University of Lahore, Pakistan
Maimoona Rasool University Institute of Radiological Sciences and Medical Imaging Technology, Faculty of Allied Health Sciences University of Lahore, Pakistan
Abstract
Background: The Presence of palpable breast mass may be an indication of breast cancer. Early and accurate diagnosis for the breast masses is important for therapeutic purpose. Purpose: To assess the diagnostic accuracy of mammographic and sonographic findings in the differentiation of palpable breast masses taking histopathology as a gold standard. Materials and Methods: 134 females were involved in the study. Sonographic and mammographic findings of palpable breast masses were obtained with the help of which diagnostic accuracy of ultrasound and mammography was calculated while taking histopathology as a gold standard. Results: Mean age in 134 females was found to be 44.2±4.7 years. Sn, Sp, PPV, NPV, disease prevalence and accuracy of ultrasound in diagnosis of palpable breast lumps were 99.09%, 79.17%, 95.61%, 95.00%, 82.09% and 95.52% respectively. Sn, Sp, PPV, NPV and accuracy of mammography in diagnosis of palpable breast lumps were 95.45%, 62.50%, 92.11%, 75.00% and 89.55% while disease prevalence was same as that of ultrasound i.e. 82.09% respectively. Conclusion: Ultrasound showed higher diagnostic accuracy in the evaluation of palpable breast masses than mammography while taking histopathology as a gold standard. It is noteworthy in differentiating breast masses.
Publication Details
Page(s) 18-24
DOI DOI not available
Published Journal: RADS Journal of Pharmacy & Pharmaceutical Sciences, Volume: 9, Issue: 1, Year: 2021

Request the full text from PASTIC

Keywords
Ultrasound, Mammography, Palpable Breast masses