No Detail Found!

Evaluation of the implant diameter on the initial-stability of narrow- and standard-diameter implants placed in simulated Type-I and Type-IV bone-blocks

Author(s)
Saad Alresayes Department of Prosthetic Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia.
Sameer A Mokeem Department of Periodontics and Community Dentistry, King Saud University, Riyadh 11545, Saudi Arabia.
Aasem M Alhenaki Department of Prosthetic Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia.
Fahim Vohra Department of Prosthetic Dental Science, King Saud University, Riyadh 11545, Saudi Arabia
Tariq Abduljabbar College of Dentistry and Research Chair for Biological Research in Dental Health, College of Dentistry, Riyadh 11545, Saudi Arabia.
Abstract
Objective: A comparison of the initial stability of narrow- and standard-diameter implants (SDIs) placed in Type-I and Type-IV bone-blocks is not yet reported. The aim was to evaluate in-vitro the influence of implant diameter on the initial stability of narrow- and standard-diameter implants (SDIs) placed in simulated Type-I and Type-IV bone-blocks. Methods: The present experimental in-vitro study was performed between July and September 2020 at the Specialist Dental Practice, Riyadh, Saudi Arabia. Narrow- and standard-diameter implants were placed 3-mm apart in simulated soft (Type-IV) and dense (Type-I) bone blocks by a trained and calibrated investigator. In groups A (Type-IV bone blocks) and B (Type-I bone blocks), implants were inserted using an insertion-torque and drilling-speed of 15-30 Ncm and 1000-1500 rpm, respectively with the implant collar at the crest of simulated bone blocks. In all samples, initial-stability was recorded using resonance frequency analysis (RFA). Sample-size estimation was done and group-comparisons were carried out. A P-value of 0.01 or less reflected statistical significance. Results: In Groups-A and -B, 44 (22 NDIs and 22 SDIs) and 44 (22 NDIs and 22 SDIs) were placed. In group-A, the mean RFA values for NDIs and SDIs were 68.5 ± 3.5 and 69.1 ± 2.4, respectively. In Group-B, the mean RFA values for NDIs and SDIs were 78.06 ± 9.6 and 75.3 ± 5.2. RFA values among NDIs and SDIs in groups A and B were similar. Conclusion: The NDIs and SDIs show comparable initial-stability when positioned in simulated Type-I and Type-IV bone blocks.
Publication Details
Page(s) 812-815
DOI DOI not available
Published Journal: Pakistan Journal of Medical Sciences, Volume: 37, Issue: 3, Year: 2021

Request the full text from PASTIC

Keywords
in-vitro, Standard diameter, initial stability, Simulated bone, Dental implant, Narrow diameter
0

Citations

0

Downloads

66

Views