No Detail Found!

ROLE OF NON COAXIAL BONE MARROW BIOPSY NEEDLE AND BONE BIOPSY NEEDLE IN CT GUIDED CORE NEEDLE BIOPSIES

Author(s)
Hassan Saleem Department of Diagnostic and Interventional Radiology, Shifa International Hospital, Islamabad - Pakistan
Atif Iqbal Rana Department of Diagnostic and Interventional Radiology, Shifa International Hospital, Islamabad - Pakistan
Ehsan Masud Kiani Department of Diagnostic and Interventional Radiology, Shifa International Hospital, Islamabad - Pakistan
Muhammad Mubashir Ramzan Department of Diagnostic and Interventional Radiology, Shifa International Hospital, Islamabad - Pakistan
Sajida Naseem Department of Community Medicine, Shifa International Hospital, Islamabad - Pakistan.
Muhammad Yousuf Chahudhary Department of Diagnostic and Interventional Radiology, Shifa International Hospital, Islamabad - Pakistan
Abstract
Objective: To compare bone marrow biopsy needle (BMBN) with bone biopsy needle (BBN) in CT guided core biopsies considering size of core, diagnostic yield and cost of needles. Methodology: Retrospective study was done on 50 out of 68 patients referred to Interventional Radiology department for CT guided bone biopsy from 2008 till 2013. Grading of specimen length was done as small, medium and large. Diagnostic yield was determined on basis of clinical, imaging and histopathology data. Local cost of both needle types was determined. Comparison was made and statistical analysis was performed. Results: Biopsy was performed by BBN in 16 patients and by BMBN in 34 patients. Overall diagnostic yield of bone biopsies was 82 % (41 of 50 biopsies). Diagnostic yield with BMBN was 85 % and with BBN was 75 %. Overall longer specimen length was obtained using BMBN. Statistically, there was no significant difference between them in diagnostic yield and specimen length; however, BMBN costs almost one half than BBN. Conclusion: Diagnostic yield and sample length using bone marrow biopsy needle proved to be equivalent to bone biopsy needle. Bone marrow biopsy needle has an added benefit of being low in cost. Despite being a non-coaxial technique these needles can achieve diagnostic yield comparable to that of coaxial techniques as reported in past literature.
Publication Details
Page(s) 231-236
DOI DOI not available
Published Journal: Journal of Postgraduate Medical Institute, Volume: 29, Issue: 4, Year: 2015

Request the full text from PASTIC

Keywords
Non-coaxial, Bone biopsy, Diagnostic yield