No Detail Found!

A Clinical Audit of Fresh Frozen Plasma Usage

Author(s)
Hamid Iqbal Armed Forces Institute of Transfusion, Rawalpindi, Pakistan.
Farhat Abbass Bhatti Armed Forces Institute of Transfusion, Rawalpindi, Pakistan.
Nuzhat Salamat Armed Forces Institute of Transfusion, Rawalpindi, Pakistan.
Fahim Akhtar Armed Forces Institute of Transfusion, Rawalpindi, Pakistan.
Kashif Hafeez Armed Forces Institute of Transfusion, Rawalpindi, Pakistan.
Abstract
Background: To assess the appropriateness of transfusions of fresh frozen plasma (FFP). Methods: In this cross sectional study use of FFP , by different departments, was analyzed. Management details and appropriateness, for the use of FFP, was recorded. British Committee for Standards in Haematology (BCSH) guidelines were used as standards. Results: Four hundred and ninety eight units of FFP were used during the study period for 118 transfusion episodes. Only 44% episodes of FFP transfusions were deemed appropriate. The most common inappropriate uses included bleeding with no coagulation test abnormality following cardiopulmonary bypass, hypovolaemia and hypoproteinaemia. The proportion of inappropriate request was similar between surgical and non surgical units. Conclusion: FFP is frequently used inappropriately.
Publication Details
Page(s) 122-124
DOI DOI not available
Published Journal: Journal of Rawalpindi Medical College, Volume: 17, Issue: 1, Year: 2013

Request the full text from PASTIC

Keywords
Fresh frozen plasma
0

Citations

0

Downloads

156