Instrumentation time and aberration incidence with endosequence rotary NiTi system in comparison to hree other commonly used rotary NiTi systems.

Author(s)
Mohammad Al-Obaida Department of Restorative Dental Sciences, College of Dentsitry, Riyadh, Kingdom of Saudi Arabia
Abstract
The aim of this study was to assess the shaping ability of Endosequence rotary NiTi system and compare it with three commonly used rotary NiTi systems. A total of sixty resin simulated root canal blocks were instrumented with EndoSequence, Pro Taper, RaCe and Profile to size #30 as MasterApical File (MAF). Pre- and post-instrumentation images were superimposed using a computer image analysis program and evaluated for presence of zipping, ledging or perforation. Further analysis was done by calculating the amount of transportation at the middle and the apical thirds. One-way analysis of variance (ANOVA) and Duncan`s multiple range tests were used for statistical analysis. EndoSequence and RaCe groups took significantly less instrumentation time compared with Profile and Pro Taper groups (P-value 0.05). The EndoSequence rotary NiTi system was found to be more efficient and safe with minimal canal aberrations in comparison with the other systems