No Detail Found!

Seismic Damage Assessment and Retrofitting of Hybrid Structure

Author(s)
O. Inderyas Department of Civil Engineering, Ege University,Izmir,Turkey
U. Ilyas Department of Civil Engineering, University of Management and Technology,Lahore,Pakistan
S.H. Farooq Department of Civil Engineering, Military College of Engineering, NUST Risalpur Campus,Risalpur,Pakistan
A. Ajwad Department of Civil Engineering, University of Management and Technology,Lahore,Pakistan
N. Khadim Department of Civil Engineering, University of Management and Technology,Lahore,Pakistan
Abstract
Pakistan is seismically prone country, which has faced devastated earthquakes in the past history. The hybrid structures are very common in northern areas of Pakistan and their behavior under seismic event is very critical. The seismic response of hybrid buildings is different from other structural systems as there is discontinuity, both in the lateral and vertical load transfer mechanisms. To assess the seismic damage of hybrid building for zone 3, the pushover analysis has been carried out on a 6-storey model building with its 4 bottom stories of reinforced concrete frame and top two stories of steel frame for a maximum drift of 2.5%. Pushover analysis has been performed using commercial software SAP2000 v.15 and critical seismic deficiencies have been determined. Overall evaluation has been done using capacity curves, stages of plastic hinge levels, storey displacements and capacity spectrum. Based on the identified deficiencies in stiffness as well as the ductility a comprehensive retrofit design has been carried out. The hybrid building has been retrofitted with shear wall or steel brace to remove the deficiencies in stiffness and ductility. After retrofitting pushover analysis has been again carried out to determine the efficiency of retrofit design. The results revealed that retrofit intervention significantly improved the seismic performance of the hybrid building and increased the stiffness or lateral capacity by 47% and 42%, respectively. Moreover, lateral displacements also have been reduced by 37% and 42% by adding shear wall and steel brace respectively. The research outcome can help the local engineers and designers to properly retrofit the existing buildings in Northern Areas of Pakistan.
Publication Details
Page(s) 144-152
DOI DOI not available
Published Journal: Nucleus, Volume: 56, Issue: 4, Year: 2019

Request the full text from PASTIC

Keywords
damage assessment, Seismic Performance, Hybrid Structure, Pushover Analysis, Retrofitting, SAP 2000 Software
0

Citations

0

Downloads

24

Views