No Detail Found!

Development and Validation of HPLC Method for the Simultaneous Determination of Insecticides (Carbofuran and Fipronil) in its Technical and Granular Formulation

Author(s)
Salman Khurshid Food Quality & Safety Research Institute, SARC, PARC, Karachi, Pakistan.
Saba Iqbal Food Quality & Safety Research Institute, SARC, PARC, Karachi, Pakistan.
Nasreen Fatima Department of Chemistry, University of Karachi, Pakistan.
Saqib Arif Food Quality & Safety Research Institute, SARC, PARC, Karachi, Pakistan.
Maaz Khurshid Department of Earth & Environmental Sciences, Bahria University Islamabad, Pakistan.
Mehwish Iqbal Food Quality & Safety Research Institute, SARC, PARC, Karachi, Pakistan.
Qurrat-ul-Ain Akber Food Quality & Safety Research Institute, SARC, PARC, Karachi, Pakistan.
Riaz-ud-Din Food Quality & Safety Research Institute, SARC, PARC, Karachi, Pakistan.
Shahid Yousaf Food Quality & Safety Research Institute, SARC, PARC, Karachi, Pakistan.
Abstract
A precise, accurate, simple and low cost reverse phase high performance liquid chromatographic (RP-HPLC) method was developed and validated for the simultaneous quality assessment of commonly used insecticide carbofuran and fipronil in its technical and formulated products. The chromatographic parameters, i.e. mobile phase composition, wavelength and flow rate of developed method was optimized in such a way that the HPLC was carried out at 280 nm by using a mobile phase, which contains 80 parts acetonitrile and 20 parts water by volume (ACN:H2O, 80:20) flowing at a rate of 1.0 mL/min. A linear relationship (R2 > 0.999) was shown by calibration curve plotted in the concentration ranged from 30-800 mg/L. The limit of detection (LODs) were found to be 14.5 mg/L and 20.9 mg/L and limit of quantification (LOQs) were recorded to be 43.9 mg/L and 63.2 mg/L for both carbofuran and fipronil respectively. The developed method’s accuracy was exhibited by recovery percentage (96.0-100.8) % of water samples spiked with 100, 300 and 600 mg/L of carbofuran and fipronil, respectively. The developed RP-HPLC method is therefore simple, cheap, rapid and can be proficiently used for the simultaneous identification and quantification of carbofuran and fipronil in its technical and formulated products.
Publication Details
Page(s) 247-253
DOI DOI not available
Published Journal: Pakistan Journal of Analytical & Environmental Chemistry, Volume: 21, Issue: 2, Year: 2020

Request the full text from PASTIC

Keywords
HPLC, Quantification, Validation, Fipronil, Carbofuran